...
首页> 外文期刊>Journal of Analytical Toxicology >A high-performance liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method for determination of risperidone and 9-hydroxyrisperidone in human plasma.
【24h】

A high-performance liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method for determination of risperidone and 9-hydroxyrisperidone in human plasma.

机译:高效液相色谱-常压化学电离-串联质谱法测定人血浆中的利培酮和9-羟基利培酮。

获取原文
获取原文并翻译 | 示例
           

摘要

Risperidone, a benzisoxazole derivative, is an antipsychotic agent used for the treatment of schizophrenia. We developed a liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric (LC-APCI-MS-MS) method with improved sensitivity, selectivity, and dynamic range for determination of risperidone and 9-hydroxyrisperidone in human plasma. A structural analogue of risperidone, RO68808 (5 ng/mL), is added as the internal standard to 1 mL of human plasma. Plasma is made basic, extracted with pentane/methylene chloride (3:1), the organic phase evaporated to dryness, and the residue is reconstituted in water with 0.1% formic acid/acetonitrile (20:1). For LC-MS-MS analysis, a Metachem Inertsel HPLC column (2.1 x 150 mm, 5-microm particle size) is connected to a Finnigan TSQ7000 tandem MS via the Finnigan API interface. Both electrospray (ESI) and APCI produced predominantly MH(+) ions for the two analytes and the internal standard. Ions detected by selected reaction monitoring correspond to the following transitions: m/z 411 to 191 for risperidone, m/z 427 to 207 for 9-hydroxyrisperidone, and m/z 421 to 201 for the internal standard. APCI provided a larger dynamic range (0.1 to 25 ng/mL) and better precision and accuracy than ESI. Intrarun accuracy and precision determined at 0.1, 0.25, 2.5, and 15 ng/mL were within 12% of target with %CVs not exceeding 10.9%. Interrun accuracy and precision determined at the same concentrations were within 9.6% of target with %CVs not exceeding 6.7%. Analytes were stable in plasma after 24 h at room temperature, 2 freeze-thaw cycles, and 490 days at -20 degrees C.
机译:利培酮是一种苯并异恶唑衍生物,是一种用于治疗精神分裂症的抗精神病药。我们开发了一种液相色谱-大气压化学电离串联质谱(LC-APCI-MS-MS)方法,具有更高的灵敏度,选择性和动态范围,可用于测定人血浆中的利培酮和9-羟基利培酮。利培酮的结构类似物RO68808(5 ng / mL)作为内标添加到1 mL人血浆中。将血浆制成碱性,用戊烷/二氯甲烷(3:1)萃取,将有机相蒸发至干,然后将残留物在含有0.1%甲酸/乙腈(20:1)的水中复溶。对于LC-MS-MS分析,通过Finnigan API接口将Metachem Inertsel HPLC柱(2.1 x 150 mm,粒径为5微米)连接到Finnigan TSQ7000串联MS。电喷雾(ESI)和APCI都主要产生两种分析物和内标物的MH(+)离子。通过选定的反应监测检测到的离子对应于以下跃迁:利培酮的m / z 411至191,9-羟基利培酮的m / z 427至207和内标的m / z 421至201。与ESI相比,APCI提供了更大的动态范围(0.1至25 ng / mL),以及更好的精度和准确性。以0.1、0.25、2.5和15 ng / mL测得的批内准确性和精密度均在目标的12%以内,%CV不超过10.9%。在相同浓度下测定的批间准确度和精密度在目标水平的9.6%之内,%CV不超过6.7%。室温下24小时,2次冻融循环以及-20摄氏度下490天后,分析物在血浆中稳定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号