Comparison of the influence of plastic and fully covered metal biliary stents on the accuracy of EUS-FNA for the diagnosis of pancreatic cancer

机译:比较塑料和完全覆盖金属胆道支架对EUS-FNA准确性诊断胰腺癌的影响

获取原文
获取原文并翻译 | 示例

摘要

Background and Study Aims: Prior studies have reported that the presence of prior biliary stent may interfere with EUS visualization of pancreatic tumors. We aimed to compare the influence of the biliary plastic and fully covered self-expanding metal stents (CSEMS) on the accuracy of EUS-FNA cytology in patients with solid pancreatic masses. Patients and Methods: We conducted a retrospective study evaluating 677 patients with solid pancreatic head/uncinate lesions and a previous biliary stent in whom EUS-FNA was performed. The patients were stratified into two groups: (1) those with a plastic stents and (2) those with CSEMS. Performance characteristics of EUS-FNA including the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were compared between the two groups. Results: The frequency of obtaining an adequate cytology by EUS-FNA was similar in both the CSEMS group and the plastic stent group (97 vs. 97.1 % respectively; p = 1.0). The sensitivity, specificity, and accuracy of EUS-FNA was not significantly different between patients with CSEMS and plastic stents (96.8, 100, 100 % and 97.3, 98, 99.8 %, respectively). The negative predictive value for EUS-FNA was lower in the CSEMS group compared to the plastic stent group (66.6 vs. 78.1 % respectively; p = 0.42). There was one false-positive cytology in the plastic stent group compared to none in the CSEMS group. Conclusions: In a retrospective cohort trial, EUS-FNA was found to be highly accurate and safe in diagnosing patients with suspected pancreatic cancer, even in the presence of a plastic or metallic biliary stent. The presence of a stent did not contribute to a higher false-positive cytology rate.
机译:背景和研究目的:先前的研究报道,先前的胆道支架的存在可能会干扰EUS对胰腺肿瘤的可视化。我们的目的是比较胆管塑料和完全覆盖的自膨胀金属支架(CSEMS)对实体胰腺肿块患者EUS-FNA细胞学准确性的影响。患者和方法:我们进行了一项回顾性研究,评估了677例具有实性胰头/尾状病变和先前行EUS-FNA的胆道支架的患者。将患者分为两组:(1)带有塑料支架的患者和(2)带有CSEMS的患者。比较两组的EUS-FNA的性能特征,包括敏感性,特异性,阳性预测值,阴性预测值和准确性。结果:CSEMS组和塑料支架组通过EUS-FNA获得足够细胞学检查的频率相似(分别为97 vs. 97.1%; p = 1.0)。 CSEMS患者和塑料支架患者之间EUS-FNA的敏感性,特异性和准确性无显着差异(分别为96.8%,100%,100%和97.3%,98%,99.8%)。与塑料支架组相比,CSEMS组对EUS-FNA的阴性预测值更低(分别为66.6%和78.1%; p = 0.42)。与CSEMS组相比,塑料支架组中只有一种假阳性细胞学检查。结论:在一项回顾性队列研究中,即使在有塑料或金属胆管支架的情况下,EUS-FNA被发现对疑似胰腺癌患者的诊断也非常准确和安全。支架的存在不会导致更高的假阳性细胞学率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号