首页> 外文期刊>Magma: Magnetic resonance materials in physics, biology, and medicine >High-resolution MR imaging appearance of colonic tissue in rabbits using an endoluminal coil
【24h】

High-resolution MR imaging appearance of colonic tissue in rabbits using an endoluminal coil

机译:腔内线圈对家兔结肠组织的高分辨率MR成像

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: This study assessed the value of high-resolution magnetic resonance imaging (MRI) of the distal colon by means of a dedicated endoluminal magnetic resonance receiver coil on a 1.5-T clinical scanner. Materials and Methods: To this end, single-loop, receive-only radio-frequency coils, housed in 18 F sheaths, were built. A 1.5-T clinical imager was used. A 18 French diameter internal MRI receiver coil was inserted into the distal colon in 15 New Zealand rabbits to obtain high-resolution magnetic resonance images by using T1-weighted Flash sequences with and without Fat Saturation (FS), T2-weighted True-Fisp, turbo spin-echo, and T1-weighted Flash FS after contrast media injection. Images were compared to histological sections. Results: An adequate image quality was obtained in all specimens without significant artefacts. Based on histological reports, a five-layer structure of the wall was considered normal. On different MR sequences, only two layers were identified on the images of all rabbits specimens. The nearest layer to the mucosal surface was usually seen as a hyper intense layer and likely corresponds to the mucosa. The highest difference of signal value between internal and external layers was performed on 2D Fat saturation T1 weighted gradient echo. Comparison of mean signal value between the internal and external layers was statistically different in for each sequence used in our protocol (P< 0.05). Conclusion: Dedicated endoluminal RF coil provides good spatial resolution at the region of interest. On this prospective study of in vivo rabbit, evaluation of colon walls allowed to provide detailed information.
机译:目的:本研究通过在1.5-T临床扫描仪上使用专用的腔内磁共振接收器线圈评估了远端结肠的高分辨率磁共振成像(MRI)的价值。材料和方法:为此,建造了容纳在18 F护套中的单回路,仅接收射频线圈。使用了1.5-T临床成像仪。将18法氏直径的内部MRI接收器线圈插入15只新西兰兔的远端结肠中,通过使用带有和不带有脂肪饱和度(FS),T2加权True-Fisp,T1加权的Flash序列获得高分辨率的磁共振图像。注入造影剂后,使用涡轮自旋回波和T1加权Flash FS。将图像与组织切片进行比较。结果:在没有明显伪像的所有标本中均获得了足够的图像质量。根据组织学报告,该壁的五层结构被认为是正常的。在不同的MR序列上,在所有兔子标本的图像上仅识别出两层。通常将最接近粘膜表面的层视为高强度层,并且可能对应于粘膜。内层和外层之间信号值的最大差异是在2D脂肪饱和度T1加权梯度回波上执行的。对于本协议中使用的每个序列,内层和外层之间的平均信号值比较在统计上是不同的(P <0.05)。结论:专用腔内RF线圈在感兴趣区域提供了良好的空间分辨率。在此对体内兔的前瞻性研究中,对结肠壁的评估可以提供详细的信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号