...
首页> 外文期刊>Veterinary Radiology & Ultrasound >T2-weighted magnetic resonance imaging measurements of optic nerve sheath diameter in dogs with and without presumed intracranial hypertension.
【24h】

T2-weighted magnetic resonance imaging measurements of optic nerve sheath diameter in dogs with and without presumed intracranial hypertension.

机译:T2加权磁共振成像测量患有和不患有颅内高压的犬的视神经鞘管直径。

获取原文
获取原文并翻译 | 示例
           

摘要

Intracranial hypertension is a cause of cerebral ischemia and neurologic deficits in dogs. Goals of this retrospective study were to test interobserver agreement for MRI measurements of optic nerve sheath diameter and associations between optic nerve sheath diameter, signalment data, and presumed intracranial hypertension status in a cohort of dogs. A veterinary radiologist interpreted scans of 100 dogs and dogs were assigned to groups based on presence or absence of at least two MRI characteristics of presumed intracranial hypertension. Two observers who were unaware of group status independently measured optic nerve diameter from transverse T2-weighted sequences. Mean optic nerve sheath diameter for all dogs was 3 mm (1-4 mm). The mean difference between observers was 0.3 mm (limits of agreement, -0.4 and 1.0 mm). There was no correlation between optic nerve sheath diameter and age for either observer (r=-0.06 to 0.00) but a moderate positive correlation was observed between optic nerve sheath diameter and body weight for both observers (r=0.70-0.76). The 22 dogs with presumed intracranial hypertension weighed less than the 78 dogs without (P=0.02) and were more often female (P=0.04). Dogs with presumed intracranial hypertension had a larger ratio of optic nerve sheath diameter to body weight for each observer-side pair (P=0.01-0.04) than dogs without. Findings indicated that the ratio of MRI optic nerve sheath diameter relative to body weight may be a repeatable predictor of intracranial hypertension in dogs.
机译:颅内高压是犬脑缺血和神经功能缺损的原因。这项回顾性研究的目的是测试观察者之间的协议,以对视神经鞘管直径进行MRI测量,以及在一组狗中视神经鞘管直径,信号数据与颅内高压状态之间的关联。兽医放射科医生解释了对100只狗的扫描,并根据是否存在假定的颅内高压的至少两个MRI特征将它们分为几组。两名不知道组状态的观察者通过横向T2加权序列独立地测量了视神经直径。所有狗的平均视神经鞘管直径为3毫米(1-4毫米)。观察者之间的平均差为0.3毫米(一致极限,-0.4和1.0毫米)。两名观察者的视神经鞘管直径与年龄之间无相关性(r = -0.06至0.00),但两名观察者的视神经鞘管直径与体重之间均存在中等正相关(r = 0.70-0.76)。 22只患颅内高压的犬的体重比没有患颅内高压的78只犬的体重轻(P = 0.02),而雌性犬的体重更多(P = 0.04)。假定为颅内高压的狗,每对观察者对的视神经鞘管直径与体重之比(P = 0.01-0.04)比没有观察者的狗更大。研究结果表明,MRI视神经鞘管直径与体重的比率可能是犬颅内高压的可重复预测指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号