首页> 外文期刊>Veterinary and Comparative Orthopaedics and Traumatology >Effect of stifle angle on the magnitude of the tibial plateau angle measurement in dogs with intact and transected cranial cruciate ligament: a cadaveric study.
【24h】

Effect of stifle angle on the magnitude of the tibial plateau angle measurement in dogs with intact and transected cranial cruciate ligament: a cadaveric study.

机译:窒息角对完整和横断的颅骨十字韧带犬的胫骨平台角测量值的影响:尸体研究。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objective: To determine the effect of stifle angle on the magnitude of the radiographictibial plateau angle (TPA) in normal and cranial cruciate ligament (CCL)-deficient stifles. Methods: Three pairs of canine cadaver hindlimbs from three skeletally mature dogs were positioned in a custom-made positioning device. A lateral radiograph of each specimen was obtained before and after transection of the CCL at four stifle angles (90 degrees , 110 degrees , 135 degrees and 140-150 degrees [i.e. maximum extension]), based on goniometric measurements. Four observers determined the radiographic TPA twice for each radiograph with a minimum of two days between each measurement. The radiographic TPA measurements in all specimens at different stifle angles with intact CCL and transected CCL were compared with mixed-model ANOVA. The effect of stifle angle, CCL transection, and interaction between the two on observer TPA measurement variability was also determined using the coefficient of variation. Results: Tibial plateau angle was not statistically different in the stifle angles for either the intact or transected CCL. There was also no statistical difference for TPA between intact and transected CCL groups at each of the stifle angles. Stifle angle, CCL transection and interaction between the two did not have any significant effect for intra-observer and inter-observer variation. Clinical significance: The angle of the stifle during radiography does not influence the magnitude of the TPA measurement as determined on true lateral radiographs of the stifle and tibia in cadaveric canine limbs.
机译:目的:确定窒息角对正常和颅交叉韧带(CCL)不足的窒息性放射照相胫骨平台角度(TPA)的影响。方法:将三对骨骼成熟的狗的三对犬尸体后肢放在定制的定位设备中。根据角度测量,以四个固定角度(90度,110度,135度和140-150度[即最大延伸度])在CCL横切之前和之后获得每个标本的侧位X线照片。四名观察员为每张射线照片两次确定了射线照相的TPA,每次测量之间至少相隔两天。将所有样品在不同固定角度和完整CCL和横切CCL的放射线TPA测量值与混合模型ANOVA进行比较。还使用变异系数确定了窒息角,CCL横切以及两者之间的相互作用对观察者TPA测量变异性的影响。结果:无论是完整的还是横切的CCL,胫骨平台角的窒息角均无统计学差异。在每个窒息角,完整和横切CCL组之间的TPA也没有统计学差异。窒息角,CCL横断和两者之间的相互作用对观察者内和观察者间的变化没有任何显着影响。临床意义:在尸检犬肢体的笔气和胫骨的真实侧面X光照片上,放射线照相术中的笔气角度不会影响TPA测量的幅度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号