首页> 外文期刊>Veterinary and Comparative Orthopaedics and Traumatology >Measurement of the patellar tendon-tibial plateau angle and tuberosity advancement in dogs with cranial cruciate ligament rupture: reliability of the common tangent and tibial plateau methods of measurement.
【24h】

Measurement of the patellar tendon-tibial plateau angle and tuberosity advancement in dogs with cranial cruciate ligament rupture: reliability of the common tangent and tibial plateau methods of measurement.

机译:颅骨十字韧带断裂犬的the腱-胫骨平台角度和结节进展的测量:常规切线和胫骨平台测量方法的可靠性。

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives: To (i) compare agreement of the common tangent (CT) and tibial plateau angle (TP) methods in terms of measuring the patellar tendon angle (PTA) and required advancement and (ii) determine the intra- and inter-observer reliability of observers who measured PTA and the advancement. Methods: Six observers were divided into three groups based on their level of experience. They measured the PTA and the required advancement on 43 radiographic images of the tibiae of dogs affected by cranial cruciate ligament rupture. Each observer repeated the measurements three times with each method. The inter-technique (interT), intra-observer (intraO), and interobserver (interO) reliabilities were evaluated, assessed by calculating the intraclass correlation coefficient (ICC), and represented by Jones plots. Results: The agreement between PTA-CT and PTA-TP was low (the ICC interT values ranged from 0.11 to 0.4). The PTA-CT was associated with moderate intra-observer reliability (ICC intraO, CT=0.61) and poor interobserver reliability (ICC interO, CT=0.33). The PTA-TP was associated with good intra-observer reliability (ICC intraO, TP=0.75) and moderate interobserver reliability (ICC interO, TP=0.59). Interobserver reliability did not depend on the level of experience. The advancement measurements were associated with reliability results similar to those obtained for PTA. Jones' plots showed that the CT method consistently yielded lower PTA and advancement values than the TP method. Conclusion: Given its poor reliability, the CT method is not recommended.Digital Object Identifier http://dx.doi.org/10.3415/VCOT-13-01-0018
机译:目的:(i)比较普通切线(CT)和胫骨平台角(TP)方法在测量pa腱角度(PTA)和所需进角方面的一致性,以及(ii)确定观察者内和观察者之间的可靠性测量PTA和进度的观察者。方法:将六名观察员根据其经验水平分为三组。他们在受颅交叉韧带断裂影响的狗的胫骨的43张放射线图像上测量了PTA和所需的进展。每个观察者用每种方法重复测量三次。评估了技术之间(interT),观察者内部(intraO)和观察者之间(interO)的可靠性,通过计算类内相关系数(ICC)进行了评估,并用琼斯图表示。结果:PTA-CT与PTA-TP之间的一致性较低(ICC interT值范围为0.11至0.4)。 PTA-CT与观察者之间的中等可靠性(ICC内部O,CT = 0.61)和较差的观察者间可靠性(ICC内部O,CT = 0.33)相关。 PTA-TP具有良好的观察者内部可靠性(ICC interO,TP = 0.75)和中等的观察者间可靠性(ICC interO,TP = 0.59)。观察员之间的可靠性不取决于经验水平。进步的测量结果与可靠性结果相关,类似于对PTA的可靠性结果。琼斯的图表明,CT法始终比TP法产生更低的PTA和进阶值。结论:由于可靠性差,不建议使用CT方法数字对象标识符http://dx.doi.org/10.3415/VCOT-13-01-0018

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号