首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >The influence of maintaining the correct whole blood-to-anticoagulant ratio during donation on the quality of leukoreduced whole blood
【24h】

The influence of maintaining the correct whole blood-to-anticoagulant ratio during donation on the quality of leukoreduced whole blood

机译:献血时维持正确的全血抗凝比对白细胞减少的全血质量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: It is unclear whether maintaining the correct whole blood-to-anticoagulant (WB : AC) ratio during collection can improve the quality of red blood cell (RBC)-containing blood products to a clinically relevant degree. STUDY DESIGN AND METHODS: A total of 2 x 20 CPDA-1 leukoreduced whole blood (WB) units suspended in CPDA-1 were investigated. In one group, AC was continuously added to the donated blood, maintaining the correct WB : AC ratio during collection, using a new drawing device (MacoPharma ABC). In the other group, WB units were produced conventionally. Adenos-ine triphosphate (ATP), 2,3-diphosphoglycerate, free hemoglobin (Hb), potassium, glucose, lactate, pH, and variables of coagulation were determined on Days 1, 7, 21, 35, 42, and 49 of storage. Variables of RBC deformability and aggregability were determined using a laser-assisted optical rotational cell analyzer. RESULTS: The ABC and conventional group showed comparable unit volumes of 525 (SD, 5.3) mL versus 524 (SD, 10.2) mL and Hb content of 65.9 (SD, 5.1) g/unit versus 67.5 (SD, 7.8) g/unit, but higher variation after conventional blood drawing (p = 0.006 and p = 0.07, respectively) was observed. During storage, none of the measured quality variables were significantly different between the groups. Mean (SD) ATP was 2.33 (0.41) mumol/g Hb versus 2.24 (0.39) mumol/g Hb after 42-day storage. Deformability was not different (p = 0.44), whereas the extent of the aggregability was higher in the conventional group (p = 0.04). CONCLUSION: The ABC device provided a better standardized blood product but did not improve RBC storage variables or plasma quality. It slightly reduced RBC aggregability during storage. Excess AC at the beginning of a donation appears not to significantly affect RBC storage in conventional blood drawing.
机译:背景:目前尚不清楚在采集过程中保持正确的全血与抗凝剂(WB:AC)比例能否在临床上将含红细胞(RBC)的血液制品的质量提高。研究设计和方法:共研究了2个20个CPDA-1悬浮在CPDA-1中的白细胞全血(WB)单位。在一组中,使用新的抽取设备(MacoPharma ABC)将AC连续添加到捐献的血液中,并在采集过程中保持正确的WB:AC比率。在另一组中,WB设备是按常规方式生产的。在储存的第1、7、21、35、42和49天确定三磷酸腺苷(ATP),2,3-二磷酸甘油酸,游离血红蛋白(Hb),钾,葡萄糖,乳酸盐,pH和凝血变量。使用激光辅助光学旋转细胞分析仪确定RBC变形能力和聚集能力的变量。结果:ABC和常规组显示相当的单位体积为525(SD,5.3)mL与524(SD,10.2)mL,Hb含量为65.9(SD,5.1)g /单位与67.5(SD,7.8)g /单位,但在常规抽血后观察到更高的变化(分别为p = 0.006和p = 0.07)。在存储过程中,两组之间没有任何测量到的质量变量存在显着差异。储存42天后,平均(SD)ATP为2.33(0.41)mumol / g Hb,而2.24(0.39)mumol / g Hb。变形能力没有差异(p = 0.44),而常规组的聚集能力更高(p = 0.04)。结论:ABC设备提供了更好的标准化血液产品,但没有改善RBC的存储变量或血浆质量。在储存过程中它略微降低了RBC的可凝集性。捐赠开始时过量的AC似乎不会显着影响常规抽血中RBC的存储。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号