首页> 外文期刊>Transactions of the ASABE >Design and evaluation of a regenerating scrubber for reducing animal house emissions.
【24h】

Design and evaluation of a regenerating scrubber for reducing animal house emissions.

机译:设计和评估可减少动物房屋排放的再生洗涤塔。

获取原文
获取原文并翻译 | 示例
           

摘要

Animal houses can emit substantial quantities of air pollutants. Compared with other pollutants, ammonia is emitted from animal houses in relatively large quantities and can have adverse public health and environmental impacts. This article describes the development and evaluation of a novel scrubber prototype, consisting of an endless polypropylene screen running in a trough of alum solution, that could be used to reduce ammonia emissions from animal houses. When building exhaust ventilation air contacts the screen, ammonia is dissolved in the aqueous solution on the screen and transported into the trough. Low ammonia concentration (<5 mg m-3) evaluations were conducted by connecting the scrubber to a pit ventilation fan in a hog finishing house. Higher ammonia concentration (7.6 to 26.6 mg m-3) evaluations were conducted by placing the scrubber inlet adjacent to a composting bin spiked with urea. Over >66 h of evaluation under low and high concentration conditions, with a weighted average air flow rate of 0.93 m3 second-1 and velocity of 0.52 m second-1, the scrubber reduced ammonia emissions by 58.3%. Compared with commercial spray and packed column scrubbers used in industry, it had a lower pressure drop (-110 Pa). It also had a low water consumption of ~1 mL m-3 treated air. Further evaluation of the scrubber in different types of animal houses and for different pollutants is required. Its design should be improved to increase ammonia removal efficiency and reduce pressure drop, footprint size, and cost. There is also need to model gas transfer in this type of scrubber.
机译:动物房屋会排放大量的空气污染物。与其他污染物相比,动物舍排放的氨量相对较大,会对公众健康和环境造成不利影响。本文介绍了一种新型洗涤塔原型的开发和评估,该洗涤塔由在明矾溶液槽中运行的无尽聚丙烯筛网组成,可用于减少动物舍的氨气排放。当建筑物的排气通风空气接触滤网时,氨会溶解在滤网上的水溶液中并输送到槽中。通过将洗涤器连接到猪场肥房的矿井通风风扇,进行低氨浓度(<5 mg m-3)评估。通过将洗涤塔入口放置在掺有尿素的堆肥箱附近,可以进行更高的氨浓度(7.6至26.6 mg m-3)评估。在低浓度和高浓度条件下,经过> 66小时的评估,加权平均空气流速为0.93 m3 second-1,速度为0.52 m second-1,洗涤塔将氨气排放量降低了58.3%。与工业上使用的商业喷雾和填充塔洗涤塔相比,它的压降更低(-110 Pa)。它还具有约1 mL m-3处理空气的低水消耗量。需要对不同类型的动物房屋中的洗涤塔和针对不同污染物的洗涤塔进行进一步评估。应该改进其设计,以提高除氨效率,减少压降,占地面积和成本。还需要对这种洗涤器中的气体传输进行建模。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号