...
首页> 外文期刊>Thrombosis Research: An International Journal on Vascular Obstruction, Hemorrhage and Hemostasis >A tetrazolium-based colorimetric assay for metabolic activity of stored blood platelets.
【24h】

A tetrazolium-based colorimetric assay for metabolic activity of stored blood platelets.

机译:基于四唑鎓的比色测定法,用于测定储存的血小板的代谢活性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

INTRODUCTION: Much work has been carried out in an attempt to establish the optimum cryopreservation of platelets. To estimate the surviving numbers of stored platelets, the metabolic redox activity of resting platelets was measured and compared with the aggregation response. MATERIALS AND METHODS: The activity was determined using a simple colorimetric assay based on reduction of a tetrazolium salt, WST-8 (4-[3-(2-methoxy-4-nitrophenyl)-2-[4-nitrophenyl]-2H-5-tetrazolio]-1,3-ben zene disulfonate sodium salt), to water-soluble formazan and its quantification with a spectrophotometer. The aggregation response of the platelets was measured at 37 degrees C with an aggregometer. RESULTS: Colored WST-8 formazan was produced in proportion to the number of intact fresh platelets, but only a little or none was produced by dead platelets lysed by sodium dodecyl sulfate (SDS), by platelets in which glycolysis had been blocked by the inhibitor monoiodoacetic acid (MIA), and by frozen platelets. The assay in conjunction with platelet aggregometry could distinguish between platelets which had lost only the aggregation response and those which had lost both aggregation response and redox activity. Freezing platelets in the presence of cryoprotectant Banbanker resulted in approximately 70% fresh platelets with redox activity and aggregation response. CONCLUSIONS: These results indicate that the WST-8 assay can be useful for identifying viable platelets independent of the aggregation response and may contribute to clarifying the mechanism of the loss of function of stored platelets.
机译:简介:为了建立最佳的血小板低温保存,已经进行了许多工作。为了估计储存的血小板的存活数量,测量了静息血小板的代谢氧化还原活性,并将其与聚集反应进行比较。材料与方法:根据简单的比色测定法,基于四唑盐WST-8(4- [3-(2-甲氧基-4-硝基苯基)-2- [4-硝基苯基] -2H- (5-四唑] -1,3-苯二磺酸钠盐)制成水溶性甲for,并用分光光度计定量。用凝集计在37℃下测量血小板的聚集反应。结果:有色的WST-8甲maz与完整的新鲜血小板数量成正比,但十二烷基硫酸钠(SDS)裂解的死血小板,其中糖酵解已被抑制剂阻断的血小板仅产生很少或不产生一碘乙酸(MIA),并通过冷冻血小板。结合血小板凝集测定的测定可以区分仅失去聚集反应的血小板和既失去聚集反应又具有氧化还原活性的血小板。在冷冻保护剂Banbanker的存在下冷冻血小板导致大约70%的新鲜血小板具有氧化还原活性和聚集反应。结论:这些结果表明,WST-8测定可用于鉴定独立于聚集反应的活血小板,并可有助于阐明储存血小板功能丧失的机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号