The influence of zero-value subtraction on the performance of two laser fluorescence devices for detecting occlusal caries in vitro.

机译:零值减法对两种激光荧光装置在体外检测咬合龋的性能的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. METHODS: The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. RESULTS: The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. CONCLUSIONS: For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. CLINICAL IMPLICATIONS: When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
机译:背景:本研究的目的是评估零值减法对开发用于检测咬合龋的两个激光荧光(LF)设备性能的影响。方法:作者选择了119个恒牙。两名检查者使用LF装置和LF笔评估了颊表面的中,远端部分和一个咬合部位的三个区域((骨,中部和子宫颈)。对于每颗牙齿,作者从在各个咬合位点测得的值中减去在颊面的牙根,中部和子宫颈区域测得的值。结果:作者观察到颊面,中部和宫颈区域中两种器械的读数之间存在差异,并且在咬合面中有零值减法和不存在零值减法的情况下,两种仪器的读数均存在差异。当作者不执行零值减法时,他们发现LF设备的灵敏度和准确性在统计学上有显着差异。用LF笔完成此操作后,特异性增加,灵敏度大大降低。结论:对于低频器件,零值减法会降低灵敏度。因此,作者得出的结论是,临床医生可以使用LF设备有效地获得措施,而无需使用零值减法。但是,对于LF笔,零值减法的缺失改变了灵敏度和特异性,因此作者得出结论,临床医生不应从手术中消除这一步骤。临床意义:使用LF设备时,临床医生可能不需要执行零值减法;但是,对于LF笔,临床医生应该这样做。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号