Comparing the reliability of a new fluorescence camera with conventional laser fluorescence devices in detecting caries lesions in occlusal and smooth surfaces of primary teeth

机译:比较新型荧光照相机与常规激光荧光设备在检测乳牙的咬合和光滑表面中的龋损中的可靠性

获取原文
获取原文并翻译 | 示例

摘要

The aims of this in vitro study were (1) to compare the reliability of a new fluorescence camera (FC; VistaProof) with that of two other laser fluorescence devices (DIAGNOdent and DIAGNOdent pen) in assessing smooth and occlusal caries lesions in primary teeth and (2) to determine the influence of the spacer, the protective cover and air drying on the FC readings. We selected 129 primary molars which were divided into two groups: smooth surfaces (n=68) and occlusal surfaces (n=61). Two trained examiners performed the evaluations using the FC and the other laser fluorescence devices separately. One examiner repeated all assessments after 1 week. Inter- and intraexaminer reproducibility was calculated from the absolute values derived from the devices using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Pearson correlation was performed among the values obtained with the different devices. For aim 2, only teeth from the occlusal surface group were used. Another examiner performed measurements with the FC, varying the size of the spacer, the use of the plastic protective cover and the drying time (0, 3 and 15 s). Wilcoxon’s test was used to compare these measurements. High values of interexaminer ICC were observed with the FC in both experiments. However, the highest intraexaminer ICC for smooth surfaces was found for the DIAGNOdent (ICC 0.918). A positive correlation between all methods was observed in both studies. Only drying for 15 s significantly increased the FC readings. In conclusion, the FC showed high reliability for occlusal and smooth surfaces, similar to the other fluorescence methods tested. Additionally, prolonged air drying increased the FC measurements.
机译:这项体外研究的目的是(1)比较新型荧光照相机(FC; VistaProof)与其他两种激光荧光设备(DIAGNOdent和DIAGNOdent笔)在评估乳牙的光滑和咬合龋病变时的可靠性。 (2)确定垫片,保护盖和空气干燥对FC读数的影响。我们选择了129个主要磨牙,将其分为两组:光滑表面(n = 68)和咬合表面(n = 61)。两名训练有素的检查员分别使用FC和其他激光荧光设备进行了评估。一位检查员在1周后重复了所有评估。使用类内相关系数(ICC)和Bland-Altman分析,从设备得出的绝对值计算出检查者之间和检查者之间的可重复性。在使用不同设备获得的值之间进行皮尔逊相关。对于目标2,仅使用来自咬合面组的牙齿。另一位检查员使用FC进行了测量,改变了垫片的尺寸,塑料保护罩的使用以及干燥时间(0、3和15 s)。 Wilcoxon的测试用于比较这些测量结果。在两个实验中,使用FC观察到的检查者间ICC值较高。但是,对于DIAGNOdent(ICC 0.918),发现光滑表面的内部检查者最高ICC。在两项研究中,所有方法之间均存在正相关。仅干燥15 s即可显着提高FC读数。总之,与其他测试的荧光方法相似,FC对咬合和光滑表面显示出高可靠性。此外,长时间的空气干燥会增加FC测量值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号