Technique for aortic valve annuloplasty using an intra-annular 'hemispherical' frame.

机译:使用环内“半球”框架进行主动脉瓣环成形术的技术。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: A need exists for a stable annuloplasty method for aortic valve repair. On the basis of a "hemispherical" model of aortic valve geometry, a prototype annuloplasty frame was constructed and initially tested. Specific goals were to develop a clinically applicable transaortic implant technique and to evaluate the system in isolated and intact animal preparations. METHODS: Eight isolated porcine aortic roots were perfused from a water reservoir at a constant pressure of 100 mm Hg, and valve leak was measured by timed collection in a beaker. Baseline leak was negligible, and the 2 commissures adjacent to the right coronary leaflet were incised vertically to create severe valve insufficiency. Through a transverse aortotomy, a "hemispherical" annuloplasty frame was sutured to the aortic valve annulus with horizontal mattress sutures. The 3 posts of the frame were sutured first to the 3 subcommissural regions to align the device horizontally and vertically. The 3 frame curvatures then were sutured into the leaflet annuli using horizontal mattress "looping" sutures, supported with supra-annular pledgets. Post-repair valve leak was measured, and significance of the change was assessed with a 2-tailed paired t test. One survival implant was evaluated in an intact calf. RESULTS: Subcommissural incision disrupted annular geometry and created a valve leak of 1400 +/- 847 mL/min (mean +/- standard deviation). Suturing the 3-dimensional annuloplasty frame into the aortic valve annulus reestablished appropriate geometry of leaflet coaptation and restored valve competence, with a reduction in valve leak to 102 +/- 86 mL/min (P = .004). After 6 weeks of chronic calf implantation, the frame was well healed and the native valve functioned normally. CONCLUSIONS: Transaortic insertion of a hemispherical porcine aortic valves routinely and effectively restored valve competence. These data support the continued development and testing of this device as a stable method of annuloplasty during aortic valve repair.
机译:目的:需要一种稳定的瓣环成形术来修复主动脉瓣。在主动脉瓣几何形状的“半球”模型的基础上,原型瓣环成形术框架得以构建并进行了初步测试。具体目标是开发一种临床上适用的经主动脉植入技术,并评估分离的完整动物制剂中的系统。方法:在100 mm Hg的恒定压力下,从储水器中灌注八个孤立的猪主动脉根,并通过定时收集在烧杯中来测量瓣膜泄漏。基线渗漏可忽略不计,并且将右冠状小叶附近的2个连合垂直切开,造成严重的瓣膜功能不全。通过横向主动脉切开术,将“半球”瓣环成形术框架缝合到具有水平褥式缝合线的主动脉瓣环上。首先将框架的3个柱子缝合到3个子接合区域,以将设备水平和垂直对齐。然后使用水平床垫“环形”缝线将3个框架曲率缝合到小叶瓣环中,并在环上瓣膜上进行支撑。测量维修后的阀门泄漏,并通过2尾配对t检验评估变化的重要性。在完整的小腿中评估一种存活植入物。结果:宫腔下切口破坏了环形几何形状,并导致瓣膜泄漏为1400 +/- 847 mL / min(平均+/-标准偏差)。将3维瓣环成形术框架缝合到主动脉瓣环中,可重新建立小叶接合的合适几何形状,并恢复瓣膜功能,同时将瓣膜渗漏降低至102 +/- 86 mL / min(P = .004)。慢性小腿植入6周后,框架恢复良好,天然瓣膜正常运作。结论:经半主动脉半球形猪主动脉瓣膜常规插入可有效恢复瓣膜功能。这些数据支持了该设备的持续开发和测试,并将其作为主动脉瓣修复过程中稳定的瓣环成形术方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号