首页> 外文期刊>The Journal of Prosthetic Dentistry >An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations
【24h】

An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations

机译:带有编码的愈合基台和不同种植体角度的种植体压痕准确性的体外比较

获取原文
获取原文并翻译 | 示例
           

摘要

Statement of problem Fabricating implant definitive casts with CAD/CAM technology (Robocasts) from coded healing abutment impressions represents a simpler and innovative alternative to conventional implant impression techniques. However, information about the accuracy of the impressions and the resultant definitive casts is limited. Purpose The purpose of the study was to evaluate the accuracy of the Robocasts and compare them to those definitive casts fabricated with conventional implant impression techniques (open tray with splinted impression copings technique). Material and methods A reference epoxy resin cast was fabricated and shaped to simulate a dental arch. Two regular platform implant replicas (Biomet 3i Certain, 4.1 mm diameter and 15 mm length) with internal connections were placed 10 mm apart with a 10-degree convergence for one side of the reference resin cast and a 30-degree convergence for the other. Coded healing abutments (Encode) were placed at 3 different heights above the level of the soft tissue replication material (approximately 1, 2, and 4 mm) and served as test groups (E1, E2, and E4), and open trays with splinted impression copings (OTSC) served as a control group. The control group was compared to the impressions of the coded healing abutments by using a standardized measurement protocol. Impressions were made for each group (n=18) and poured with vacuum mixed (100 g powder/20 mL water) Type IV dental stone. The vertical discrepancy (Z axis) between 2 prefabricated passively fitting titanium reference frameworks and the platforms of the implant replicas was measured with an optical comparator applying the 1 screw test. Data were analyzed with Kruskal-Wallis and post-hoc Mann-Whitney U tests, as well as the Wilcoxon signed-rank tests. The Bonferroni correction was used to account for multiple comparisons. The significance level (α) used in a given set of tests was equal to.05 divided by the number of tests performed in that set. Results The median vertical discrepancy of each coded healing abutment impression group was higher than the corresponding median of the control group (OTSC) for every combination of angulation and position. Kruskal-Wallis tests indicated a statistically significant difference (P<.001) between groups for each angulation/position combination. All post hoc Mann-Whitney U tests indicated statistically significant differences (all P≤.002) between OTSC and the other groups. Differences between the angulations and positions were not statistically significant when accounting for multiple comparisons. Conclusions The implant definitive casts fabricated from the coded healing abutment impressions were found to be less accurate than those fabricated from the open tray with splinted impression copings technique for restoring 2 paired (10 or 30 degrees) convergent internal connection implants with nonengaging screw-retained splinted 2-unit implant restorations. Accuracy of fit was not influenced by the implant angulation or position for either impression technique or by the Encode healing abutment height for the Encode impression technique.
机译:问题陈述通过编码的愈合基台压痕,使用CAD / CAM技术(Robocast)制造植入物确定型铸件,是传统植入物压痕技术的一种更简单,创新的替代方案。但是,有关印象的准确性和最终确定的类型的信息是有限的。目的本研究的目的是评估机器人铸造的准确性,并将其与使用常规植入物压模技术(带有夹板压模顶盖技术的开放式托盘)制造的确定型铸件进行比较。材料和方法制作参考环氧树脂铸件并成型以模拟牙弓。将两个带有内部连接的常规平台植入物复制品(Biomet 3i Some,直径4.1毫米,长度15毫米)分开放置10毫米,参考树脂铸件的一侧为10度会聚,另一侧为30度会聚。将已编码的愈合基台(Encode)放置在软组织复制材料上方大约3个不同的高度(大约1、2和4 mm),并用作测试组(E1,E2和E4),并打开带有夹板的托盘印象应对(OTSC)作为对照组。通过使用标准化的测量方案,将对照组与编码的愈合基台的印模进行比较。对每组(n = 18)进行印象,并倒入真空混合(100g粉末/ 20mL水)IV型牙石。使用光学比较器应用1个螺钉测试,测量2个预制的被动装配钛参考框架与种植体复制品平台之间的垂直差异(Z轴)。使用Kruskal-Wallis和事后Mann-Whitney U检验以及Wilcoxon秩和检验对数据进行了分析。 Bonferroni校正用于进行多次比较。给定测试集中使用的显着性水平(α)等于.05除以该测试集中执行的测试数量。结果对于每个角度和位置组合,每个编码的愈合基台印模组的中值垂直差异均高于对照组(OTSC)的相应中值。 Kruskal-Wallis测试表明,每种角度/位置组合的组之间在统计学上有显着差异(P <.001)。所有事后的Mann-Whitney U检验均表明OTSC与其他组之间存在统计学上的显着差异(所有P≤.002)。考虑多重比较时,角度和位置之间的差异在统计上并不显着。结论发现,用编码的愈合基台压模制造的植入物确定性铸件不如使用夹板压痕顶盖技术从开放式托盘制造的用于修复2对(10度或30度)会聚的内部连接植入物和未接合的螺钉固定夹板的铸件精确。 2个单元的种植体修复体。贴合精度不受印模技术的植入物角度或位置或编码印模技术的编码愈合基台高度的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号