STATEMENT OF PROBLEM: In severely compromised dentition, loading of long-span and cantilever metal-ceramic fixed partial dentures (FPDs) could result in framework deformation and porcelain fractures. The use of cobalt-chromium (Co-Cr) alloys may be advantageous, but there is little information on the longevity of, and complications with, prostheses made with these alloys. PURPOSE: The aim of this retrospective study was to report the survival and complication rates of Co-Cr metal-ceramic FPDs and crowns followed over a 3- to 7-year period. MATERIAL AND METHODS: The study included 42 patients with a total of 51 FPDs and 12 single crowns assigned to 1 of 3 groups. The 3 groups comprised patients with abutment teeth with a questionable prognosis (n=10), advanced chronic periodontitis (n=19), or abutment teeth with a positive prognosis (n=13). The FPDs had a mean of 9.7 units (range of 3-14). Of the FPDs, 32 were provided with a cantilever on 1 side (n=24) or both sides (n=8). The mean observation time was51 months (range of 28-82). All patients were examined by 2 independent prosthodontists using the California Dental Association (CDA) assessment system for evaluation. One-way ANOVA with Fisher's LSD post hoc test and the Mann-Whitney U test were used for statistical analyses (alpha=.05). RESULTS: Seventeen (34%) of the FPDs had biological and/or technical complications. Six (12%) FPDs were completely or partially removed during the observation period, 1 framework fractured, and 9 (17.6%) FPDs had ceramic fractures. Fifteen of the 21 fractured FPD units were related to FPDs that were placed in 3 patients with bruxing habits. The CDA rating for marginal integrity was "excellent" for more than 98% of the abutments. No patients reported adverse reactions to the material. CONCLUSIONS: Metal-ceramic FPDs made of cobalt-chromium alloy performed acceptably in the questionable prognosis and advanced chronic periodontitis groups.
机译:问题陈述:在严重受损的牙列中,大跨度和悬臂式金属陶瓷固定局部义齿(FPD)的加载可能导致框架变形和瓷器断裂。钴铬(Co-Cr)合金的使用可能是有利的,但是关于这些合金制成的假体的寿命和并发症的信息很少。目的:这项回顾性研究的目的是报告在3至7年内Co-Cr金属陶瓷FPD和牙冠的存活率和并发症发生率。材料与方法:该研究纳入了42例患者,共51片FPD和12个单冠,分配给3组中的1组。这三组患者的基牙预后可疑(n = 10),晚期慢性牙周炎(n = 19)或预后阳性的基牙(n = 13)。 FPD的平均值为9.7个单位(范围为3-14)。在FPD中,有32个在一侧(n = 24)或两侧(n = 8)都设有悬臂。平均观察时间为51个月(范围为28-82)。所有患者均由2位独立的牙齿修复专家使用加利福尼亚牙科协会(CDA)评估系统进行了评估。统计分析采用单向方差分析,Fisher LSD事后检验和Mann-Whitney U检验进行。结果:FPD中有17个(34%)具有生物学和/或技术并发症。在观察期间,全部或部分去除了6个(12%)FPD,1个框架断裂,并且9个(17.6%)FPD出现陶瓷断裂。在21个破裂的FPD单元中,有15个与放置在3个有瘀伤习惯的患者中的FPD有关。超过98%的基台的CDA边缘完整性评价为“优秀”。没有患者报告对该材料有不良反应。结论:钴铬合金制成的金属陶瓷FPD在可疑的预后和晚期慢性牙周炎组中表现良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号