首页> 美国卫生研究院文献>The Journal of the Indian Prosthodontic Society >Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study
【2h】

Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study

机译:铸造固定局部义齿与两种不同贱金属合金制成的焊接固定局部义齿的边缘精度的比较评估和铸造技术:体外研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni–Cr and Cr–Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr–Co samples and 20 Ni–Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr–Co samples when compared to Ni–Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.
机译:基牙的牙周健康状况和固定局部义齿的耐久性取决于假体的边缘适应性。边缘区域的任何差异都会导致诱剂溶解和斑块积聚。进行这项研究的目的是评估在感应铸造和离心铸造下由Ni-Cr和Cr-Co合金制成的四个单元冠和桥的边缘配合的精度。将它们与铸造固定局部义齿(FPD)和焊接FPD进行了比较。为了本研究的目的,制作了金属模型。总共准备了40个样品(4单元冠和桥),其中制造了20个Cr-Co样品和20个Ni-Cr样品。在每组的这20个样品中,通过感应铸造技术制备了10个样品,而其他10个样品通过离心铸造技术制备了。将获得的铸造FPD样品放置在模型上,然后用精度为0.001 cm的移动显微镜测量样品。在两个桥体之间进行样品切片并进行测量,然后使用焊枪焊接单元进行焊接。测量焊接样品的边际差异,并对所有发现进行统计分析。结果表明,与采用感应铸造技术进行的Ni-Cr样品相比,Cr-Co样品的边际差异最小。与铸造FPD样品相比,焊接组的边际差异减小了。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号