Objective: To determine whether resuscitation teams can better maintain newborn transitional oxygen saturation (SpO2) values within a prespecified target range using a graphical display of the targets and real-time SpO2 data compared with using only numerical oximeter values. Study design: Preterm neonates were enrolled in this prospective cohort evaluation of a change in practice. The Transitional Oxygen Targeting System (TOTS) plots real-time SpO2 values in relation to 10th and 50th percentile SpO2 curves, which provides a visual target. After introduction of the TOTS, the resuscitation team adjusted the fraction of inspired oxygen to maintain the SpO2 within the target range, and before its use neonates were resuscitated in attempt to target normal transitional SpO 2 values without using the TOTS monitor. Duration of time within 10th-50th percentile values was compared between 2 cohorts, children evaluated with the TOTS and those not evaluated with the TOTS (controls). Results: A total of 40 infants were enrolled, including 20 prospectively evaluated with the TOTS and 20 controls. Mean gestational age, birth weight, total resuscitation time, duration of supplemental oxygen administration, changes in oxygen concentration, and respiratory support provided were similar in the 2 groups. The TOTS cohort spent 52% of time within the target range; the control cohort, 37% (P =.03). Conclusion: SpO2 values were maintained within a specified target range for significantly longer in preterm neonates resuscitated using the TOTS display compared with those resuscitated without TOTS.
机译:目的:通过图形化显示目标值和实时SpO2数据,而不是仅使用数字血氧仪值,来确定复苏小组能否更好地将新生儿过渡性氧饱和度(SpO2)值保持在预定目标范围内。研究设计:早产新生儿参加了这项针对实践变化的前瞻性队列评估。过渡氧气靶向系统(TOTS)绘制了与第10和第50个百分位数SpO2曲线相关的实时SpO2值,从而提供了可视目标。引入TOTS后,复苏小组调整了吸入氧气的比例,以将SpO2维持在目标范围内,并且在使用新生婴儿之前,对新生儿进行了复苏,以尝试使用正常的SpO2正常值而不使用TOTS监护仪。比较了2个队列,使用TOTS评估的儿童和未使用TOTS评估的儿童(对照组)在10%至5​​0%百分数值内的持续时间。结果:共纳入40例婴儿,包括20例使用TOTS进行的前瞻性评估和20例对照。两组的平均胎龄,出生体重,总复苏时间,补充氧气的施用时间,氧气浓度的变化和提供的呼吸支持相似。 TOTS队列花费了目标范围内52%的时间;对照人群为37%(P = .03)。结论:与未进行TOTS复苏的早产儿相比,使用TOTS进行复苏的早产儿的SpO2值维持在指定的目标范围内的时间更长。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号