This paper is the second in a series of two describing the performance of a miniature and low-weight respirable sampler designed to fit inside filtering facepiece (FFP) and half-mask type respirators. The first paper described the design of the miniature sampler and evaluated the particle and collection performance of the miniature sampler. This paper assesses its comparability with the traditional inward leakage measurement technique, and its safe use. Simultaneous mass measurements of a respirable sodium chloride aerosol were taken inside a total inward leakage chamber by a miniature sampler and by sodium flame photometry. Direct side-by-side comparison of the two methods yielded excellent correlation (R-2 = 0.99), as did comparison when sampling from inside four different masks when worn by a breathing Sheffield dummy head. In addition, comparison tests were carried out using three models of FFP worn by human volunteers both with and without the miniature sampler, in order to test whether or not the presence of the miniature sampler negatively affected the protection offered. The difference between the tests carried out with the miniature sampler and without the miniature sampler was not statistically significant (P = 0.3). In all cases, the masks performed within their protection class, whether the miniature sampler was fitted or not. We therefore conclude that the miniature sampler does not significantly affect the protection offered by the masks. The miniature sampler may prove a viable option for in-mask measurements of respirable dust where low air concentrations of hazardous material are expected.
机译:本文是两个系列文章中的第二篇,介绍了设计用于过滤式口罩(FFP)和半罩式防毒面具内部的微型,低重量可吸入式采样器的性能。第一篇论文描述了微型采样器的设计,并评估了微型采样器的颗粒和收集性能。本文评估了它与传统的内向泄漏测量技术的可比性,以及它的安全使用。通过微型采样器和钠焰光度法在总向内泄漏室内对可吸入氯化钠气雾剂进行同时质量测量。两种方法的直接并排比较产生了极好的相关性(R-2 = 0.99),呼吸Sheffield假人佩戴时从四个不同面罩内部采样时的比较也是如此。此外,使用带有和不带有微型采样器的人类志愿者佩戴的三种FFP模型进行了对比测试,以测试微型采样器的存在是否会对所提供的保护产生负面影响。在使用微型采样器和不使用微型采样器的情况下进行的测试之间的差异无统计学意义(P = 0.3)。在所有情况下,无论是否安装了微型采样器,口罩都在其防护等级内执行。因此,我们得出的结论是,微型采样器不会显着影响面罩提供的保护。微型采样器可能被证明是可吸入粉尘的面罩内测量的可行选择,其中可预期空气中的有害物质浓度较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号