The relationship between dust size and penetration for a static horizontal elutriator (Sibata C-30) was measured in calm air. The elutriator as a low-volume air sampler is widely used as a dust size classifier in work environment measurements. The actual penetrations were compared with the theoretical models of the sampler and with sampling convention for respirable dust in work environment measurement. The sampling convention was recently introduced into the Japanese standard for work environment measurement and is based on the ISO 7708 respirable dust convention. The bias of sampled masses from the respirable dust was calculated for two flow rates of the sampler, i.e., 50% cut sizes of 4 microm and 5 microm, from measured penetration curves. The bias of the sampler was overestimated in the 5 microm, 50% cut condition and underestimated in the 4 microm, 50% cut condition for most workplace sampling situations.
机译:在安静的空气中测量了静态卧式淘析器(Sibata C-30)的粉尘大小与渗透率之间的关系。淘析器作为一种小体积的空气采样器,被广泛用作工作环境测量中的灰尘尺寸分级器。将实际的渗透率与采样器的理论模型以及工作环境测量中可吸入粉尘的采样约定进行了比较。采样约定最近已被引入日本的工作环境测量标准中,并基于ISO 7708可吸入粉尘约定。对于采样器的两种流速,即根据测得的穿透曲线,计算了可吸入粉尘的采样质量偏差,即50%切割尺寸为4微米和5微米。对于大多数工作场所采样情况,在5微米,50%切割条件下高估了采样器的偏差,而在4微米,50%切割条件下低估了采样器的偏差。