首页> 外文期刊>The Journal of arthroplasty >Dissociation of modular total hip arthroplasty at the femoral head-neck interface after loosening of the acetabular shell following hip dislocation.
【24h】

Dissociation of modular total hip arthroplasty at the femoral head-neck interface after loosening of the acetabular shell following hip dislocation.

机译:髋关节脱位后髋臼壳松动后,在股骨头-颈部界面处进行模块化全髋关节置换术。

获取原文
获取原文并翻译 | 示例
           

摘要

Modular component dissociation is a potential problem of current modular total hip arthroplasty (THA) systems. We describe a case of dissociation of the modular THA at the femoral head-neck interface after loosening of the acetabular shell during closed reduction for posterior dislocation of THA. The causes of this dissociation and acetabular shell loosening are discussed. Successful treatment was provided with surgical revision of the acetabular and the femoral head components. The present case serves as a graphic reminder that the acetabular shell overhanging the acetabular bone must be avoided when implanting modular THA components.
机译:模块化组件分离是当前模块化全髋关节置换术(THA)系统的潜在问题。我们描述了在髋臼后壁脱位的闭合复位过程中髋臼壳松动后在股骨头-颈部接口处分离模块THA的情况。讨论了这种分离和髋臼壳松动的原因。手术矫正髋臼和股骨头组件提供了成功的治疗方法。本例作为图形提醒,在植入模块化THA组件时,必须避免髋臼外罩超出髋臼骨。