...
首页> 外文期刊>The Journal of Antimicrobial Chemotherapy >Phenotypic detection of mecC-MRSA: Cefoxitin is more reliable than oxacillin
【24h】

Phenotypic detection of mecC-MRSA: Cefoxitin is more reliable than oxacillin

机译:mecC-MRSA的表型检测:头孢西丁比奥沙西林更可靠

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: To investigate the reliability of cefoxitin and oxacillin for the detection of mecC-positive Staphylococcus aureus. Methods: The susceptibility to cefoxitin and oxacillin of 62 mecC-positive S. aureus isolateswas investigated using broth microdilution, agar dilution, Etest and disc diffusion on different types of media. The data were interpreted for the utility of cefoxitin and oxacillin in conjunction with the stated methodologies for the detection of mecC-positive isolates. Results: Cefoxitin with Mueller-Hinton media fromBecton Dickinson and Oxoid detected all mecC-positive isolates when tested by broth microdilution, agar dilution and disc diffusion. By Etest, one isolate was falsely susceptible. Mueller-Hinton agar from bioMérieux was substantially less able to detect these isolates. One isolate was falsely susceptible by agar dilution when using Iso-Sensitest and Columbia agar. Disc diffusion using cefoxitin on Iso- Sensitest agar missed 29% of the isolates. For oxacillin, only agar dilution on Columbia agar+2% NaCl was able to detect all mecC-positive isolates successfully. Conclusions:Cefoxitin used withEUCASTmethodologyandoxacillin used with agardilutiononColumbia agar+2% NaCl detected all mecC-positive isolates. These methods with their concomitant agars should be preferred over Iso-Sensitest, which is recommended by the BSAC. It should be noted that for disc diffusion Mueller-Hinton media from bioMérieux performed poorly, with 26%-47% of mecC isolates being falsely susceptible.
机译:目的:探讨头孢西丁和奥沙西林在检测mecC阳性金黄色葡萄球菌中的可靠性。方法:采用肉汤微稀释,琼脂稀释,Etest和圆盘扩散在不同类型的培养基上,研究了62株mecC阳性金黄色葡萄球菌对头孢西丁和奥沙西林的敏感性。结合头孢西丁和奥沙西林的效用,结合陈述的检测mecC阳性分离株的方法,对数据进行了解释。结果:通过肉汤微稀释,琼脂稀释和圆盘扩散检测时,头孢西丁与来自Becton Dickinson的Mueller-Hinton培养基和Oxoid一起检测到所有mecC阳性分离株。通过Etest,一个隔离株是错误地易感的。来自bioMérieux的Mueller-Hinton琼脂检测这些分离株的能力大大降低。使用Iso-Sensitest和Columbia琼脂时,一种分离株对琼脂稀释错误地敏感。使用头孢西丁在异敏琼脂上进行的椎间盘扩散漏出了29%的分离株。对于奥沙西林,只有在哥伦比亚琼脂+ 2%NaCl上稀释琼脂才能成功检测出所有mecC阳性分离株。结论:头孢西丁与EUCAST方法结合使用,奥沙西林与琼脂稀释在哥伦比亚琼脂+ 2%NaCl上一起检测到所有mecC阳性分离株。这些方法及其伴随的琼脂应优于BSAC建议的Iso-Sensitest。应当指出,对于光盘扩散,来自bioMérieux的Mueller-Hinton培养基效果不佳,其中26%-47%的mecC分离株易受感染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号