首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Comparison of direct current, derivative direct current, pulse and square wave voltammetry at single disc, assembly and composite carbon electrodes: stripping voltammetry at thin film mercury microelectrodes with field-based instrumentation
【24h】

Comparison of direct current, derivative direct current, pulse and square wave voltammetry at single disc, assembly and composite carbon electrodes: stripping voltammetry at thin film mercury microelectrodes with field-based instrumentation

机译:单盘电极,组合电极和复合碳电极上的直流电,导数直流电,脉冲和方波伏安法的比较:薄膜汞微电极上的基于现场仪器的溶出伏安法

获取原文
获取原文并翻译 | 示例
       

摘要

A comparative investigation of normal and stripping forms of voltammetry was undertaken at single and random array microdisc, macrodisc and composite carbon electrodes using dc, derivative dc, square-wave and differential-pulse waveforms, Studies on the reduction of [Fe(CN)(6)](3-) in 0.05 M KNO3 revealed that the dc waveform with derivative readout is superior to the use of square-wave or differential-pulse waveforms at both single disc and random array carbon fibre electrodes, Analytical superiority to that obtained at a conventional glassy carbon macrodisc electrode was also observed. The detection limit for the determination of [Fe(CN)(6)](3-) was 4 x 10(-6) M at the carbon fibre random array microdisc electrode and 6 x 10(-6) M when using a single disc microelectrode (scan rate = 200 mV s(-1)), For the determination of Pb and Cd in 0.1 M HCl by stripping voltammetry, the ideal combination of high sensitivity (greater than or equal to 1 ppb detection limit), avoidance of the need to remove oxygen or utilise solution stirring or electrode rotation could be achieved at mercury-plated thin film single disc or random array microelectrodes or composite electrodes. Furthermore, under these thin film conditions, the analytical performance of each of these three electrode types improved with respect to signal-to-background current ratio as the scan rate increased. Consequently, short potential scanning times as well as optimum sensitivity are achieved with scan rates in the 1-50 V s(-1) range. All of the results obtained demonstrate that highly sensitive field-based voltammetric analysis may be accomplished using the combination of an inherently simple two-electrode battery operated instrument, the de waveform and random array or single carbon fibre microdisc working electrodes, An interface which enables voltammetric studies to be undertaken with a battery operated personal computer is described for this purpose. [References: 7]
机译:使用直流,导数直流,方波和微分脉冲波形在单阵列和随机阵列微盘,大盘和复合碳电极上对伏安法的正常和剥离形式进行了比较研究,研究了[Fe(CN)( 6)](3-)在0.05 M KNO3中显示,具有导数读出的dc波形在单盘和随机阵列碳纤维电极上均优于使用方波或微分脉冲波形,在分析上的优势优于在还观察到常规的玻璃状碳大盘电极。用于测定[Fe(CN)(6)](3-)的检测限在碳纤维随机阵列微盘电极上为4 x 10(-6)M,在使用单个电极时为6 x 10(-6)M圆盘微电极(扫描速率= 200 mV s(-1)),用于通过溶出伏安法测定0.1 M HCl中的Pb和Cd,是高灵敏度(大于或等于1 ppb检测极限)的理想组合,避免了在镀汞薄膜单盘或随机阵列微电极或复合电极上,可以实现除氧或利用溶液搅拌或电极旋转的需求。此外,在这些薄膜条件下,随着扫描速率的增加,这三种电极类型中每一种的分析性能相对于信号本底电流比均得到改善。因此,在1-50 V s(-1)范围内的扫描速率下,可以实现较短的潜在扫描时间以及最佳灵敏度。所有获得的结果表明,可以结合使用本质上简单的两电极电池操作的仪器,去波形和随机阵列或单碳纤维微盘工作电极的组合来完成基于高灵敏度场的伏安分析,实现伏安的界面为此,将描述用电池供电的个人计算机进行的研究。 [参考:7]

著录项