Multidimensional analysis of instant coffee and barley beverage samples using size exclusion chromatography (SEC) combined with a dynamic surface tension detector (DSTD) and a UV-vis absorbance detector (UV) is reported. A unique finding of this study was the action of the tetrabutylammonium (TBA) cation as a modifying agent (with bromide as the counter anion) that substantially increased the surface pressure signal and sensitivity of many of the proteins in the chromatographically separated samples. The tetrabutylammonium bromide (TBAB) enhancement of the surface pressure signal was further investigated by studying the response of 12 commercial standard proteins (a-lactalbumin, beta-lactoglobulin, human serum albumin (HSA), albumin from chicken egg white (OVA), bovine serum albumin (BSA), hemoglobin, alpha-chymotrypsinogen A, cytochrome C, myoglobin, RNase A, carbonic anhydrase, and lysozyme) in buffer performed using flow injection analysis (FIA) coupled with the DSTD with and without various concentrations of TBAB. The FIA-DSTD data show that 1 mM TBAB enhances sensitivity of HSA detection, by lowering the limit of detection (LOD) from 2 mg/mL to 0.1 mg/mL Similarly, the LOD for BSA was reduced from 1 mg/mL to 0.2 mg/mL These FIA-DSTD experiments allowed the detection conditions to be optimized for further SEC-UV/DSTD experiments. Thus, the SEC-UV/DSTD system has been optimized and successfully applied to the selective analysis of surface-active protein fractions in a commercial instant coffee sample and in a soluble barley sample. The complementary selectivity of using the DSTD relative to an absorbance detector is also demonstrated.
机译:据报道,使用尺寸排阻色谱(SEC)结合动态表面张力检测器(DSTD)和紫外可见吸收剂检测器(UV)对速溶咖啡和大麦饮料样品进行多维分析。这项研究的独特发现是四丁基铵(TBA)阳离子作为改性剂(以溴化物为抗衡阴离子)的作用,该作用大大提高了色谱分离样品中的表面压力信号和许多蛋白质的灵敏度。通过研究12种商业标准蛋白(α-乳白蛋白,β-乳球蛋白,人血清白蛋白(HSA),鸡卵清蛋白(OVA),牛)的响应,进一步研究了四丁基溴化铵(TBAB)对表面压力信号的增强作用使用流动注射分析(FIA)与DSTD结合使用和不使用各种浓度TBAB的DSTD,在缓冲液中进行血清白蛋白(BSA),血红蛋白,α-胰凝乳蛋白酶原A,细胞色素C,肌红蛋白,RNase A,碳酸酐酶和溶菌酶的缓冲液的分析FIA-DSTD数据显示,通过将检测限(LOD)从2 mg / mL降低到0.1 mg / mL,1 mM TBAB增强了HSA检测的灵敏度。同样,BSA的LOD从1 mg / mL降低到0.2 mg / mL这些FIA-DSTD实验可以优化检测条件,以用于进一步的SEC-UV / DSTD实验。因此,SEC-UV / DSTD系统已经过优化,已成功应用于商业速溶咖啡样品和可溶性大麦样品中表面活性蛋白组分的选择性分析。还展示了使用DSTD相对于吸光度检测器的互补选择性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号