Accuracy of bladder volume determinations by ultrasonography: are they accurate over entire bladder volume range?

机译:通过超声检查确定的膀胱容量的准确性:在整个膀胱容量范围内,它们是否准确?

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: To investigate the accuracy of a portable three-dimensional hand-held BladderScan (BS) and two-dimensional conventional ultrasonography (CUS) in the estimation of bladder volumes. METHODS: The bladder volume of 65 subjects was measured during filling cystometry using two ultrasound modalities. Serial measurements were performed when the infused volume reached 100, 200, 300, and 400 mL; the investigator measured the volumes three times each with BS and CUS. Each corresponding true volume was calculated by interpolation using zero volume and the final catheterized volume at the end of cystometry. The accuracy of the two ultrasound methods was compared using raw scaled values of the volumes and the percentage of differences of volume. RESULTS: Bladder volumes determined by CUS and BS were underestimated by 21.8% and 3.3% (mean values), respectively. The percentage of differences of volume of BS was not statistically significant (P >0.05), but that of CUS was statistically significant (P <0.00001). No significant percentage of differences of volume change according to the volume status was observed by either ultrasound measurement method (P >0.05). Linear regression analysis between the true volumes and the raw scaled volumes showed that the slope of the BS was closer to 1.0 than that of the CUS, and the difference was statistically significant (P <0.001). The effects of diagnosis, age, sex, and body mass index were not significant in determining the bladder volume by either method (P >0.05). CONCLUSIONS: Our results demonstrated that a three-dimensional hand-held scanner measures the bladder volume in a reproducible and accurate manner for a wide range of bladder volumes and is superior to two-dimensional stationary ultrasonography.
机译:目的:研究便携式三维手持式BladderScan(BS)和二维常规超声检查(CUS)在估计膀胱容量方面的准确性。方法:采用两种超声方式在充盈性膀胱测压法中测量65名受试者的膀胱体积。当注入量达到100、200、300和400 mL时,进行系列测量。研究人员分别用BS和CUS测量了三遍。通过使用零体积和在膀胱测压术结束时的最终导管插入量进行插值来计算每个对应的真实体积。使用原始的体积比例值和体积差异百分比比较了两种超声方法的准确性。结果:由CUS和BS确定的膀胱体积分别低估了21.8%和3.3%(平均值)。 BS的体积差异百分比无统计学意义(P> 0.05),而CUS的体积差异具有统计学意义(P <0.00001)。两种超声测量方法均未观察到根据体积状态的体积变化差异的显着百分比(P> 0.05)。真实体积和原始比例体积之间的线性回归分析表明,BS的斜率比CUS的斜率更接近1.0,并且差异具有统计学意义(P <0.001)。通过两种方法确定膀胱体积时,诊断,年龄,性别和体重指数的影响均不显着(P> 0.05)。结论:我们的结果表明,三维手持式扫描仪可在广泛的膀胱体积范围内以可重复且准确的方式测量膀胱体积,并且优于二维固定超声检查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号