...
首页> 外文期刊>Ultrasound in obstetrics & gynecology: the official journal of the International Society of Ultrasound in Obstetrics and Gynecology >Interobserver repeatability of three- and four-dimensional transperineal ultrasound assessment of pelvic floor muscle anatomy and function.
【24h】

Interobserver repeatability of three- and four-dimensional transperineal ultrasound assessment of pelvic floor muscle anatomy and function.

机译:观察者之间的可重复性,经盆腔底肌肉的解剖学和功能的经会阴和三维三维评估。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To evaluate the interobserver repeatability of measurement of the pubovisceral muscle and levator hiatus, and the position of related organs, during rest, muscle contraction and Valsalva maneuver using three- and four-dimensional (3D and 4D) transperineal ultrasound. METHODS: Seventeen women were included in the study. The position and dimensions of the pubovisceral muscle and levator hiatus in patients at rest and during contraction and Valsalva were determined from stored 3D and 4D ultrasound volumes. Analyses were conducted offline by two observers blinded to the clinical data and to each others' measurements. RESULTS: Measurements of levator hiatal dimensions at rest demonstrated intraclass correlation coefficient (ICC) values of 0.92 to 0.96. The ICC values for pubovisceral muscle thickness at rest varied between good and very good (ICC, 0.61-0.93), regardless of plane. During contraction, the ICC values for all measured parameters were very good, varying between 0.61 and 0.92. Measurement of the transverse diameter of the levator hiatus during the Valsalva maneuver showed good reliability (ICC, 0.86), but assessment of the anterior and posterior borders of the levator hiatus was only possible in 29% of cases. CONCLUSIONS: 3D and 4D transperineal ultrasound measurement of the pubovisceral muscle and levator hiatus is reliable in women with no or minor symptoms of prolapse at rest and during contraction. The technique for recording during the Valsalva maneuver requires improvement if it is to be useful in the diagnosis of pelvic organ prolapse.
机译:目的:评估在休息,肌肉收缩和Valsalva动作期间使用三维和三维(3D和4D)经会阴超声测量耻骨内脏肌和提肌裂孔以及相关器官位置的观察者之间的可重复性。方法:17名妇女被纳入研究。根据储存的3D和4D超声体积确定静息时,收缩时和Valsalva患者的耻骨内脏肌和提肌裂孔的位置和大小。两名观察员对临床数据和彼此的测量结果视而不见,进行了离线分析。结果:静息时提肛裂孔尺寸的测量表明组内相关系数(ICC)值为0.92至0.96。不论平面如何,静息时耻骨内脏肌厚度的ICC值在良好和非常好之间变化(ICC,0.61-0.93)。收缩期间,所有测量参数的ICC值都非常好,介于0.61和0.92之间。在Valsalva手术中测量提肛裂孔的横向直径显示出良好的可靠性(ICC,0.86),但是仅在29%的病例中可以评估提肛裂孔的前缘和后缘。结论:3D和4D经会阴超声测量耻骨内脏肌和提肌裂孔对于在休息和收缩过程中没有或有轻微脱垂症状的女性是可靠的。如果要在诊断盆腔器官脱垂中有用的话,瓦尔萨尔瓦(Valsalva)操纵期间的记录技术需要改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号