首页> 外文期刊>Prehospital emergency care >Noninvasive fireground assessment of carboxyhemoglobin levels in firefighters.
【24h】

Noninvasive fireground assessment of carboxyhemoglobin levels in firefighters.

机译:消防员中的羧基血红蛋白水平的非侵入性评估。

获取原文
获取原文并翻译 | 示例

摘要

Objectives. Carboxyhemoglobin (COHb) levels can be estimated by chemical analysis of exhaled alveolar breath. Such noninvasive measurement could be used on the fireground to screen both firefighters (FFs) and victims. The purpose of this study was to assess the feasibility of using a hand-held carbon monoxide (CO) monitoring device to screen for CO toxicity in FFs under field conditions. Methods. Informed consent was obtained from all participants. Using a hand-held breath CO detection device, COHb readings were collected at baseline, and then as FFs exited burning buildings after performing interior fire attack and overhaul with self-contained breathing apparatus (SCBA) during live-fire training. Ambient CO levels were occasionally measured in interior areas where the FFs were working to assess the degree of CO exposure. Results. Baseline COHb readings of 64 FFs ranged from 0% to 3% (mean 1%, median 1%). One hundred eighty-four COHb readings were collected during training exercises. The mean and median COHb levels were 1%. The maximum value in a FF wearing SCBA was 3%; values of 14%, 5%, and 4% were measured in instructors who were not properly wearing SCBA. Ambient CO readings during fire attack ranged from 75 to 1,290 ppm, and the ambient CO reading for overhaul ranged from 0 to 130 ppm. When the device was used for interior CO monitoring, washout time limited its utility for COHb monitoring in FFs. Conclusions. A hand-held CO monitoring device adapted for estimation of COHb levels by exhaled breath analysis can feasibly be deployed on the fireground to assess CO exposure in FFs.
机译:目标。可以通过呼出的肺泡呼吸的化学分析来估计碳氧合血红蛋白(COHb)的水平。这种非侵入性测量可以在火场上使用,以筛查消防员(FF)和受害者。这项研究的目的是评估在田间条件下使用手持式一氧化碳(CO)监测设备筛查FF中的CO毒性的可行性。方法。所有参与者均已获得知情同意。使用手持式呼吸CO检测设备,在基线时收集COHb读数,然后当实况射击训练期间,FF在进行内部火灾袭击并用自给式呼吸器(SCBA)进行大修后离开燃烧的建筑物时,收集COHb读数。有时在FF负责评估CO暴露程度的内部区域中测量环境CO水平。结果。 64个FF的基线COHb读数范围为0%至3%(平均1%,中位数1%)。在训练演习中收集了184个COHb读数。平均和中位数COHb水平为1%。穿FF的SCBA的最大值为3%;在没有正确穿着SCBA的教练中测得的数值分别为14%,5%和4%。发生火灾时的环境CO读数范围为75至1,290 ppm,大修时的环境CO读数范围为0至130 ppm。当该设备用于内部CO监测时,冲洗时间限制了其用于FF中COHb监测的效用。结论。适于通过呼气分析评估COHb水平的手持式CO监测设备可以在火场上可行地部署,以评估FF中的CO暴露。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号