Usually, during a fire inside a tunnel, the average heat release rate (HRR) is estimated according to the type of vehicle. Frequently, the overall HRR is considered, however it is also necessary to know its time evolution to design real time systems, particularly ventilation, which respond to fire events or signals as fast as possible. Nowadays, there is not a well established and generally accepted procedure to know the power liberated at each instant of time inside an operational tunnel. That procedure could help in taking the correct actions to adapt the tunnel ventilation in order to diminish the effects of the fire and the smoke. This work shows a method to calculate the heat release rate using sensors that can be installed inside an operational road tunnel. Besides, the location of the fire could also be calculated accurately and quickly. To achieve the previous purposes, a stationary database that depends on HRR, its location, and the ventilation speed is calculated with CFD programs; the data are compared with temperatures measured by the sensors located inside the tunnel. The program used to generate the database is the simplified model UPMTUNNEL. The predictions of the model are compared with the results of calculations carried out using the general purpose code FLUENT, and with measurements done in a tunnel with a real fire, produced with a fuel tray.
机译:通常,在隧道内发生火灾时,根据车辆类型估算平均放热率(HRR)。通常会考虑整个HRR,但是也有必要了解其时间演变,以设计实时系统,尤其是通风系统,以尽可能快地响应火灾或信号。如今,尚没有一个完善的,公认的程序来知道运行隧道内每个时刻释放的功率。该程序可以帮助采取正确的措施来适应隧道的通风,以减少火灾和烟雾的影响。这项工作显示了一种使用传感器的方法来计算放热率,该传感器可以安装在可运行的公路隧道内。此外,还可以准确,快速地计算出火灾的地点。为了实现上述目的,使用CFD程序计算了一个依赖于HRR,其位置和通风速度的固定数据库。将数据与位于隧道内的传感器测得的温度进行比较。用于生成数据库的程序是简化模型UPMTUNNEL。将模型的预测与使用通用代码FLUENT进行的计算结果进行比较,并与在使用燃料托盘产生的真实火灾隧道中进行的测量进行比较。

著录项

  • 来源
    《Tunnelling and underground space technology 》 |2011年第1期| p.211-222| 共12页
  • 作者单位

    Laboratorio de Mecanica de Fluidos, Departamento de Ingenieria Energetica y Fluidomecanica, Escuela Tecnica Superior Ingenieros Industrials (ETSII), Universidad Politecnica de Madrid (UPM), C/Jose Gutierrez Abascal, 2 - 28006 Madrid, Spain;

    Laboratorio de Mecanica de Fluidos, Departamento de Ingenieria Energetica y Fluidomecanica, Escuela Tecnica Superior Ingenieros Industrials (ETSII), Universidad Politecnica de Madrid (UPM), C/Jose Gutierrez Abascal, 2 - 28006 Madrid, Spain;

    Laboratorio de Mecanica de Fluidos, Departamento de Ingenieria Energetica y Fluidomecanica, Escuela Tecnica Superior Ingenieros Industrials (ETSII), Universidad Politecnica de Madrid (UPM), C/Jose Gutierrez Abascal, 2 - 28006 Madrid, Spain;

    EUROESTUDIOS, Ingenieria de Consulta, C/Casteilo, 128 - 28006 Madrid, Spain;

    EUROESTUDIOS, Ingenieria de Consulta, C/Casteilo, 128 - 28006 Madrid, Spain;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    heat release rate; road tunnel fire; pool fire; zone model; CFD; full-scale experiments;