The flexural behaviour of eaves, apex and base connections for cold-formed steel single C-section portal frames is investigated through a series of connection tests and analyses of corresponding finite element models. The moment-rotation characteristics of the eaves, apex and base connections from the respective connection tests and the numerical models indicate good agreement between. The attainment of ultimate load by the eaves and the apex connection was normally preceded by significant deformation of connecting brackets. The eaves connections reached its ultimate load capacities upon fracture of screws or ply bearing of M8 bolts on the C-section lips while the apex connections attained their ultimate load capacities with the formation of inelastic buckling near the compression flange-web junction of one of the adjoining beams. The base connection tests exhibited large rotational deformation and capacity to deform with inelasticity mostly concentrated in the connector bracket. Based on the tests and numerical analyses, simplified nonlinear moment-rotation relations are established for eaves, apex and base connections.
机译:通过一系列的连接试验和对相应有限元模型的分析,研究了冷弯型钢单C型截面门框的屋檐,顶点和基础连接的抗弯性能。屋檐,顶点和基础连接的力矩旋转特性来自各个连接试验和数值模型,表明两者之间具有良好的一致性。屋檐和顶点的连接通常会在达到最大载荷之前先使连接支架发生明显变形。屋檐连接处达到最大极限承载能力,原因是螺钉断裂或C形截面唇缘上的M8螺栓层合支撑,而顶点连接达到其极限承载能力,其中之一是在压缩法兰-腹板连接处附近形成无弹性屈曲。相邻的横梁。基础连接测试显示出较大的旋转变形和变形能力,且缺乏弹性,变形主要集中在连接器支架中。根据试验和数值分析,建立了屋檐,顶点和基础连接的简化非线性力矩-旋转关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号