首页> 外文期刊>Thin-Walled Structures >Diaphragm performance of cold-formed steel floors with steel form-deck and gypsum-based self-leveling underlayment
【24h】

Diaphragm performance of cold-formed steel floors with steel form-deck and gypsum-based self-leveling underlayment

机译:具有钢模板和石膏基自流平衬砌的冷弯钢地板的横隔板性能

获取原文
获取原文并翻译 | 示例
           

摘要

Cold-formed steel composite floor systems are being widely used in cold-formed steel framing for mid-rise building construction, primarily because of their structural and economic efficiency. This study investigated the diaphragm performance of cold-formed steel composite floors through cyclic load testing and numerical simulation. The composite floors consist of cold-formed steel C-shaped joists and a subfloor with cold-formed steel form-deck and gypsum-based self-leveling underlayment. The test results indicated that the primary failure mode of the specimens was shear failure of the self-drilling screws that connected the steel form-deck and end joists. A finite element model was developed and validated with the test results in terms of hysteretic curves, failure modes, and seismic performance indices such as the ultimate load-bearing capacity and stiffness degradation. Moreover, extensive parametric studies were conducted using the proposed models. The results of analyses showed that the spacing of the screws connecting the steel form-deck to the joists at the floor perimeter and as well as the floor aspect ratio have significant impacts on the diaphragm performance. By contrast, the thickness of the gypsum-based self-leveling underlayment, joist depth, and web perforations exert only a minor influence on the diaphragm performance. Finally, a simplified method was proposed to calculate the central displacement of composite floors based on theoretical analysis. This study provides a useful design basis for the design and application of cold-formed steel composite floors in engineering practice.
机译:主要由于其结构和经济效率,冷弯型钢复合地板系统已广泛用于中高层建筑的冷弯型钢框架。本研究通过循环载荷试验和数值模拟研究了冷弯型钢复合地板的隔板性能。复合地板由冷弯的C型钢托梁和一个带有冷弯的钢模板和石膏基自流平衬砌的底层地板组成。测试结果表明,试样的主要破坏模式是连接钢模板和端梁的自钻螺钉的剪切破坏。开发了有限元模型,并根据滞回曲线,破坏模式和抗震性能指标(例如极限承载力和刚度退化)对测试结果进行了验证。此外,使用建议的模型进行了广泛的参数研究。分析结果表明,在地板周长处将钢模板与桁架连接的螺钉的间距以及地板的长宽比对振动膜的性能有重大影响。相比之下,石膏基自流平垫层的厚度,托梁深度和腹板穿孔对膜片性能的影响很小。最后,基于理论分析,提出了一种简化的方法来计算复合地板的中心位移。该研究为冷弯型钢复合地板在工程实践中的设计和应用提供了有用的设计依据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号