首页> 外文OA文献 >Structural performance of shear resisting connections between cold-formed steel sections using web cleats of cold-formed steel strip
【2h】

Structural performance of shear resisting connections between cold-formed steel sections using web cleats of cold-formed steel strip

机译:冷弯型钢腹板夹板在冷弯型钢之间的抗剪连接结构性能

摘要

The paper presents an investigation on the structural performance of shear resisting connections between cold-formed steel sections where web cleats of cold-formed steel strips are used to attach beams to supporting beams and columns. A total of 24 connection tests with four different connection configurations were carried out; three modes of failure were identified: failure of fasteners shear buckling of cold-formed steel web cleats or webs of supported beams, and lateral torsional buckling of cold-formed steel web cleats The structural performance of the cold-formed steel web cleats in four different connection configurations is presented in detail. It is demonstrated that cold-formed steel web cleats may be used with bolts or self-drilling self-tapping screws as practical shear resisting connections in building construction. A set of design rules is formulated in accordance with both BS5950: Part 5 and Eurocode 3: Part 1.3 after calibration against test data. The rationalized usage of cold-formed steel web cleats allows simple and effective connections to be formed between cold-formed steel sections leading to improved buildability.
机译:本文对冷弯型钢之间的抗剪连接的结构性能进行了研究,其中冷弯型钢的腹板防滑板用于将梁连接到支撑梁和柱上。总共进行了24种具有四种不同连接配置的连接测试。确定了三种破坏模式:紧固件的破坏,冷弯型钢夹板或支撑梁的腹板的剪切屈曲,冷弯型钢夹板的横向扭转屈曲。冷弯型钢夹板的结构性能在四种不同的情况下详细介绍了连接配置。事实证明,冷成型钢网夹板可与螺栓或自钻自攻螺钉一起使用,作为建筑结构中的实用抗剪连接。根据测试数据校准后,根据BS5950:第5部分和欧洲规范3:第1.3部分制定了一套设计规则。合理使用冷弯型钢腹板防滑钉,可以在冷弯型钢之间形成简单有效的连接,从而提高了可建造性。

著录项

  • 作者

    Chung KF; Lawson RM;

  • 作者单位
  • 年度 2000
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利