首页> 外文期刊>Radioelectronics and Communications Systems >CALIBRATION OF A MULTIPORT ANALYZER OF MICROWAVE NETWORKS BASED ON DFT TAPPED SIGNALS WITH THE AID OF SHORT-CIRCUITED WAVE RESISTANCE STANDARDS
【24h】

CALIBRATION OF A MULTIPORT ANALYZER OF MICROWAVE NETWORKS BASED ON DFT TAPPED SIGNALS WITH THE AID OF SHORT-CIRCUITED WAVE RESISTANCE STANDARDS

机译:借助短波波阻标准对基于DFT敲击信号的微波网络多端口分析仪的校准

获取原文
获取原文并翻译 | 示例

摘要

A new method is suggested for calibration of the 6-port analyzer of microwave networks The analyzer, using DFT of tapped signals, has a set of standard short-circuited loads. The calibration algorithm includes two steps. First, we solve a system of linear equations for some intermediate variables introduced. Second, we calculate the real and imaginary parts of the equivalent complex-valued constants by solving a linear or nonlinear (with zero initial approximations) system of equations. Simulation of the calibration procedure confirmed the efficiency of the calibration algorithm.
机译:建议使用一种新方法来校准微波网络的6端口分析仪。该分析仪使用抽头信号的DFT,具有一组标准的短路负载。校准算法包括两个步骤。首先,我们为引入的一些中间变量求解线性方程组。其次,我们通过求解线性或非线性(初始近似值为零)方程组来计算等效复数值常数的实部和虚部。校准过程的仿真证实了校准算法的效率。