首页> 外文期刊>Radiation Protection Dosimetry >DOSE-AREA PRODUCT MEASUREMENTS AND DETERMINATION OF CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSE IN DENTAL LATERAL CEPHALOMETRIC RADIOLOGY
【24h】

DOSE-AREA PRODUCT MEASUREMENTS AND DETERMINATION OF CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSE IN DENTAL LATERAL CEPHALOMETRIC RADIOLOGY

机译:牙科侧向头颅放射学中有效剂量的剂量区产品测量和转换系数的确定

获取原文
获取原文并翻译 | 示例
           

摘要

A study has been carried out to propose diagnostic reference levels (DRLs) for lateral cephalometric radiology in Germany based on the dose-area product (DAP). DRLs were proposed separately for child and adult exposure settings which are 26.4 and 32.6 mGy cm~2, respectively. Organ absorbed doses from lateral cephalometric radiology were also measured using thermoluminescence detectors (TLDs) and an adult anthropomorphic phantom specially design for dosimetric study in dental radiology. Effective doses were then calculated using three different techniques where the salivary gland and brain tissue were given different weighting factors. Conversion coefficients for estimating effective dose from DAP value derived in this study range from 0.042 to 0.149 uSv/mGy cm~2.
机译:已经进行了一项研究,以基于剂量面积积(DAP)提出德国侧头X线放射学的诊断参考水平(DRL)。针对儿童和成人的暴露设置分别提出了DRL,分别为26.4和32.6 mGy cm〜2。还使用热致发光检测器(TLD)和专为牙科放射学进行剂量学研究而设计的成人拟人体模,测量了从侧面头颅放射学吸收的器官剂量。然后使用三种不同的技术计算有效剂量,其中唾液腺和脑组织被赋予不同的加权因子。根据本研究得出的DAP值估算有效剂量的转换系数范围为0.042至0.149 uSv / mGy cm〜2。