...
首页> 外文期刊>Radiation Protection Dosimetry >MICRODOSIMETRIC CHARACTERISTICS OF 50 kV X RAYS AT DIFFERENT DEPTHS FOR BREAST INTRAOPERATIVE RADIOTHERAPY
【24h】

MICRODOSIMETRIC CHARACTERISTICS OF 50 kV X RAYS AT DIFFERENT DEPTHS FOR BREAST INTRAOPERATIVE RADIOTHERAPY

机译:乳腺癌术中放疗不同深度50 kV X射线的微剂量学特征

获取原文
获取原文并翻译 | 示例
           

摘要

An intraoperative radiation therapy (IORT) device with SO kV X rays was designed to deliver a single dose to the tumour bed after local excision of breast cancer. The quality of a radiation can be determined by the microscopic distribution of energy transfers along and across the charged particle tracks. The lineal energy, y, serves as an accurate measure of local energy concentration. The dose mean lineal energy, y_D, is an indicator of radiation quality. For low linear energy transfer radiation, the ratio of its dose mean lineal energy to that of Co gamma rays can serve as a good indicator of the relative biological effectiveness (RBE) at low doses. In this study, microdosimetric simulations are performed for soft tissue irradiated by 50 kV X rays generated from the IORT device, with a 4-cm breast applicator attached. All energy transfers are recorded with the location coordinates in the tissue. Microdosimetric single events in a sphere of 1 μm in diameter are scored as a function of radial distances from the applicator surface. Single-event spectra are then constructed. From those single-event spectra, dose mean lineal energy is calculated. Compared with dose mean lineal energy of ~(60)Co gamma rays, the estimated RBEs at low doses are given for the X rays at different depths in the tissue. The RBEs at clinically relevant doses, as a function of depth, are also presented.
机译:设计了具有SO kV X射线的术中放射治疗(IORT)设备,可在乳腺癌局部切除后向肿瘤床单剂量给药。辐射的质量可以通过沿着和穿过带电粒子轨道的能量转移的微观分布来确定。线性能量y可以精确地测量局部能量的浓度。剂量平均线性能量y_D是辐射质量的指标。对于低线性能量转移辐射,其剂量平均线性能量与Coγ射线的剂量之比可以作为低剂量下相对生物学有效性(RBE)的良好指标。在这项研究中,对从IORT装置产生的50 kV X射线照射的软组织进行微剂量模拟,并连接了4厘米的乳房涂药器。所有的能量转移都以组织中的位置坐标记录下来。直径为1μm的球体中的微剂量单事件根据与施药器表面的径向距离进行评分。然后构造单事件光谱。从这些单事件光谱中,可以计算出剂量平均线性能量。与〜(60)Co伽玛射线的剂量平均线性能量相比,针对低剂量的估计RBE给出了组织中不同深度的X射线。还介绍了临床相关剂量的RBE,随深度变化。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2015年第4期|343-346|共4页
  • 作者单位

    Department of Radiation Oncology, Columbia University, New York, USA;

    Department of Radiation Oncology, Mount Sinai Medical Center, New York, USA;

    Radiation Protection Bureau, Health Canada, Ottawa, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号