首页> 外文期刊>IEEE Transactions on Power Delivery >Performance of metal-oxide arresters exposed to ferroresonance in padmount transformers
【24h】

Performance of metal-oxide arresters exposed to ferroresonance in padmount transformers

机译:金属氧化物避雷器在平板式变压器中遭受铁磁谐振的性能

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Ferroresonant overvoltages have been recognized as a threat to arresters installed on underground distribution systems. Extensive tests have been performed to evaluate the thermal and electrical performance of MOV arresters exposed to this duty. Arrester discharge currents were found to be small and arrester heating is slow. The eventual temperature rise and the potential for thermal instability depends greatly on the type of arrester. Arrester designs which promote better heat dissipation to the ambient are shown to reach an acceptable steady-state temperature when exposed to ferroresonance of indefinite duration.
机译:铁磁过电压被认为是对安装在地下配电系统上的避雷器的威胁。已经进行了广泛的测试,以评估暴露在该职责下的MOV避雷器的热和电性能。发现避雷器放电电流很小,避雷器加热缓慢。最终的温度升高和热不稳定性的可能性在很大程度上取决于避雷器的类型。当暴露于无限期的铁磁谐振时,促进更好地向周围环境散热的避雷器设计可达到可接受的稳态温度。