首页> 外文期刊>IEEE Transactions on Power Delivery >Electromagnetic compatibility of high voltage transmission linesand the guidance of center pivot irrigation units with cornering systems
【24h】

Electromagnetic compatibility of high voltage transmission linesand the guidance of center pivot irrigation units with cornering systems

机译:高压输电线路的电磁兼容性以及带转弯系统的中心枢轴灌溉单元的导向

获取原文
获取原文并翻译 | 示例

摘要

A study was carried out to determine if electromagnetic fields ofnhigh voltage transmission lines can interfere with electromagneticallynguided cornering systems associated with some center pivot irrigationnunits. Using electromagnetic susceptibility tests, it was found that 60nhertz magnetic fields of more than approximately 500 mG (milligauss) arenrequired to cause interference with the operation of one system. Thisnlevel is significantly higher than those found near most high voltagentransmission lines. It was also found that the magnetic fields atnharmonic frequencies and wideband fields due to corona on thentransmission line studied were insufficient to cause interference withncornering guidance systems. Observations of center pivot corneringnsystems operating properly near 345 kV transmission lines in Nebraska,nUSA, confirmed these results
机译:进行了一项研究以确定高压输电线路的电磁场是否会干扰与某些中心枢轴灌溉单元相关的电磁引导转弯系统。使用电磁敏感性测试,发现需要60赫兹以上的磁场(大约500 mG以上)来干扰一个系统的运行。该水平显着高于大多数高压n传输线附近的水平。还发现,在研究的传输线上由于电晕产生的非谐频率磁场和宽带场不足以引起对角引导系统的干扰。对美国内布拉斯加州345 kV输电线路附近正常运行的中心枢轴转弯系统的观察证实了这些结果