This paper has investigated the possibility of glass insulator breakage by resonance and accelerated degradation based on an analysis of natural frequency characteristics of glass insulators on the KTX overhead line and behavioral characteristics of the overhead line on site. The natural frequencies were formed within the range of 10 kHz, and the largest amplitude was observed at 5.15 kHz. The largest frequency that was imposed on strut tube glass insulators was 80 Hz with 1.13 g of vertical vibration in the viaduct section, the largest vertical vibration (0.38 g) was detected at 103 Hz in the open route section. When site frequency and natural frequency of strut tube glass insulators were compared in terms of characteristics, the resonance was not the same. In both the viaduct and open route sections, it seems that the impact by vertical vibration in strut tube glass insulators is large. Through this study, therefore, it has been confirmed that the failure of the glass insulator has nothing to do with resonance. In addition, no damage was detected in the accelerated degradation test.
机译:本文通过对KTX架空线路上的玻璃绝缘子的固有频率特性和现场架空线路的行为特性进行分析,研究了谐振器和加速退化引起的玻璃绝缘子破裂的可能性。固有频率在10 kHz的范围内形成,并且在5.15 kHz处观察到最大振幅。在高架桥段中,施加在支撑管玻璃绝缘子上的最大频率为80 Hz,垂直振动为1.13 g,在开放通道段中,最大垂直振动(0.38 g)在103 Hz下检测到。从特性上比较支柱管玻璃绝缘子的固有频率和固有频率时,共振不同。在高架桥部分和开放路径部分中,似乎在支柱管玻璃绝缘子中,垂直振动的影响很大。因此,通过这项研究,已经证实玻璃绝缘子的故障与共振无关。此外,在加速降解试验中未发现损坏。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号