首页> 外文期刊>IEEE Transactions on Power Delivery >Chromatic Optoacoustic Monitoring of Transformers and Their Onload Tap Changers
【24h】

Chromatic Optoacoustic Monitoring of Transformers and Their Onload Tap Changers

机译:变压器及其有载分接开关的彩色光声监测

获取原文
获取原文并翻译 | 示例

摘要

This contribution presents the rationale, basis, and potential for continuous and event-driven online chromatic acoustic monitoring of transformers and their tap changers. Illustrations are given from a feasibility project for monitoring transformers at several substation sites in the Manchester and Stoke regions of the U.K. Examples of monitoring outputs are presented in a top-down order of information compression, representing an approach that is tailorable to substation operators' information requirements for tracking and tracing overall and individual tap change quality. It is concluded that the approach is feasible for trend sampling and continuous monitoring regimes. Ongoing work includes the evaluation of overall transformer acoustic behavior patterns and individual internal tap-change elements. The monitoring is being rolled out to 50 transformers.
机译:这一贡献为变压器及其分接开关连续和事件驱动的在线色声监测提供了理论依据,基础和潜力。举例说明了在英国曼彻斯特和斯托克地区多个变电站现场监视变压器的可行性项目,监视输出示例以自上而下的信息压缩顺序呈现,代表了一种适合变电站运营商信息的方法跟踪和跟踪整体和单个分接开关质量的要求。结论是,该方法对于趋势采样和连续监视机制是可行的。正在进行的工作包括评估整体变压器的声学行为模式和各个内部抽头转换元件。监视正在部署到50个变压器。