首页> 外文期刊>IEEE Transactions on Plasma Science >Influence of electrode and insulator materials on the neutron emission in a low energy plasma focus device
【24h】

Influence of electrode and insulator materials on the neutron emission in a low energy plasma focus device

机译:电极和绝缘体材料对低能等离子体聚焦装置中子发射的影响

获取原文
获取原文并翻译 | 示例

摘要

Insertion of internal impurities is one of the factors for the degradation of neutron output in plasma focus devices. In this context, neutron emission measurements were carried out in a 2.2 kJ (7.2 /spl mu/F, 25 kV) Mather type squirrel cage plasma focus device with various combinations of electrode and insulator materials. The neutron yield was measured by silver activation detector. The results indicate that a central electrode of low erosion rate material produces maximum neutron yield with the highest anisotropy factor. A time integrated X-ray pinhole image shows that focus corresponding to the highest neutron yield material is the most compressed. The dielectric constant of the ceramic insulators has, at best, a very weak correlation with neutron output. The nonceramic insulators like perspex, nylon, or teflon neither produce focus nor neutrons.
机译:内部杂质的插入是等离子聚焦装置中中子输出退化的因素之一。在这种情况下,中子发射测量是在2.2 kJ(7.2 / spl mu / F,25 kV)马瑟型鼠笼式等离子体聚焦装置中进行的,其中电极和绝缘体材料的组合多种多样。通过银活化检测器测量中子产率。结果表明,低腐蚀速率材料的中心电极可产生最大的中子产率,且各向异性系数最高。时间积分X射线针孔图像显示,对应于最高中子产率材料的焦点被压缩得最多。陶瓷绝缘子的介电常数充其量与中子输出之间的联系非常弱。诸如有机玻璃,尼龙或特氟隆之类的非陶瓷绝缘子既不会产生聚焦点,也不会产生中子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号