Dichromate and ethanol-chlorobenzene dosimeters were studied in conditions of annual temperature changes during process control at the Radiation Unit of the Vinca Institute. Measurements were performed in February (10-14℃) and August (22-35℃) for the dose range 10-50 kGy. The difference between measurements using these dosimeters is in agreement with the previous laboratory studies of temperature effect on the dose response of a dichromate dosimeter. The absorbed doses measured by these two dosimeters are in good agreement and the difference is within a limit of 3% for the studied dose range. The uncertainties of dose measurements using dichromate dosimeter arising from irradiation during annual temperature changes appear to be well within acceptable limits indicating that this dosimeter can be used as a routine dosimeter.
机译:在Vinca研究所辐射装置的工艺控制过程中,在年度温度变化的条件下研究了重铬酸盐和乙醇-氯苯剂量计。在2月(10-14℃)和8月(22-35℃)进行了10-50 kGy剂量范围的测量。使用这些剂量计进行测量之间的差异与先前温度对重铬酸盐剂量计剂量响应的实验室研究一致。这两个剂量计测量的吸收剂量非常吻合,对于所研究的剂量范围,差异在3%的范围内。由年度温度变化期间的辐照引起的使用重铬酸盐剂量计的剂量测量不确定性似乎在可接受的范围内,这表明该剂量计可以用作常规剂量计。