An all-metal bellows chamber with a comb-type Radio Frequency (RF) shield for a high-current accelerator was developed and tested at the KEK B-factory (KEKB). The comb-type RF shield has no thin fingers but has nested comb teeth instead at an inner surface. The comb-type RF-shield has a higher thermal strength structurally compared to the conventional finger-type one. Leakage of the TE mode like HOM through the RF shield is almost suppressed. Two test models of bellows chambers installed in the 3.5 GeV positron ring of KEKB showed good properties up to a stored beam current of 1.5 A. The temperature rise of the corrugation was about 7℃ and the temperature rise was about 1/6 of that of the bellows chamber with a conventional finger-type RF shield located under the same condition. The temperature rise of the comb teeth was about 22℃, while that of fingers of the finger-type RF shield was estimated to be about 105℃ for the equivalent HOM power. No vacuum arcing was detected during beam operation.
机译:在KEK B工厂(KEKB)开发并测试了带有大电流加速器的梳状射频(RF)屏蔽的全金属波纹管腔。梳型RF屏蔽罩没有细的手指,但是在其内表面有嵌套的梳齿。与传统的手指型相比,梳型RF屏蔽在结构上具有更高的热强度。几乎可以抑制TE模式(例如HOM)通过RF屏蔽的泄漏。在KEKB的3.5 GeV正电子环中安装的两种波纹管腔的测试模型表现出良好的性能,直至储存的束流为1.5 A。波纹的温升约为7℃,温升约为波纹的1/6。波纹管腔室在相同条件下具有常规的手指型RF屏蔽层。等效HOM功率时,梳齿的温度上升约为22℃,而手指型RF屏蔽的手指的温度上升约为105℃。在光束操作过程中未检测到真空电弧。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号