A study of the spectroscopic response of several large-size CdTe detectors equipped with a conventional cathode and a multi-microstrip anode (15 strips, each 150 μm wide, 500 μm pitch) was carried out. Measurements were performed scanning the detector across the strips, by means of a narrow rectangular photon beam (~(57)Co and ~(109)Cd sources), with its longer side oriented parallel to the strip direction, at normal incidence, in order to evaluate the detector behavior when the photon beam impinges at the strip position and at different positions inside the gaps. The detectors were also irradiated changing the value of the angle θ between the photon beam direction and the normal to the cathode surface in the range 0°< θ< 70°. The behaviors of the 14, 22, 88 and 122 keV energy peaks have been analyzed. From the scanning along and across the strips some degree of spatial non-uniformity has been observed. As expected, the spectroscopic performance of microstrip detectors is only slightly dependent on the angle, i.e. our strip design is working well. Further measurements are in progress to study the observed charge sharing between adjacent strips, in order to understand if these detectors are suitable to be used as position sensitive devices with spectroscopic capabilities to build up focal planes of X-ray telescopes for astrophysics applications.
机译:进行了几个配备了常规阴极和多微带阳极(15条,每条宽150μm,间距500μm)的大型CdTe检测器的光谱响应研究。通过窄矩形光子束(〜(57)Co和〜(109)Cd源),以垂直于入射方向的较长边平行于条带方向的方式,在整个条带上扫描检测器,进行测量当光子束撞击到条带位置和间隙内的不同位置时,评估探测器的行为。还照射检测器,以在0°<θ<70°的范围内改变光子束方向与阴极表面的法线之间的角度θ的值。分析了14、22、88和122 keV能量峰值的行为。从沿着条带和横过条带的扫描可以观察到一定程度的空间不均匀性。不出所料,微带检测器的光谱性能仅略微取决于角度,即我们的条形设计运行良好。为了了解这些检测器是否适合用作具有光谱功能的位置敏感设备,以建立用于天体物理学的X射线望远镜的焦平面,正在进行进一步的测量以研究观察到的相邻条带之间的电荷共享。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号