The building of a demonstration fast breeder reactor (DFBR) plant in Japan is planed to be base isolated in the horizontal direction. To verify the seismic safety of the isolation system, a series of shaking table tests was conducted using a reduced scale model with three types of base isolation system, natural rubber bearing with steel damper (NRB+SD), lead rubber bearing (LRB), and high damping rubber bearing (HRB). The results of these tests showed NRB+SD, LRB and HRB were within the stable domain (not hardening) at 1×S2 (maximum acceleration 3.80 m S~-2) input, and were nearly hardening at 2×S2 input. None of the rubber bearings broke at 3×S2 input, which was The design limit. All these bearings broke at over 4×S2 input.
机译:计划在日本建造示范快速增殖反应堆(DFBR)厂,使其在水平方向上与基地隔离。为了验证隔震系统的地震安全性,我们使用缩减比例模型对三种基本隔震系统进行了一系列振动台测试,其中三种类型的基础隔震系统为带钢减震器的天然橡胶轴承(NRB + SD),铅橡胶轴承(LRB),和高阻尼橡胶轴承(HRB)。这些测试的结果表明,NRB + SD,LRB和HRB在1×S2(最大加速度3.80 m S〜-2)输入时处于稳定区域(未硬化),而在2×S2输入时几乎硬化。在3×S2输入下,没有一个橡胶轴承破裂,这是设计极限。所有这些轴承在超过4×S2的输入时就破裂了。