首页> 外文期刊>Mechanical systems and signal processing >Detection of a static eccentricity fault in a closed loop driven induction motor by using the angular domain order tracking analysis method
【24h】

Detection of a static eccentricity fault in a closed loop driven induction motor by using the angular domain order tracking analysis method

机译:角域阶次跟踪分析法检测闭环感应电动机的静态偏心故障

获取原文
获取原文并翻译 | 示例

摘要

In this study, a new method was presented for the detection of a static eccentricity fault in a closed loop operating induction motor driven by inverter. Contrary to the motors supplied by the line, if the speed and load, and therefore the amplitude and frequency, of the current constantly change then this also causes a continuous change in the location of fault harmonics in the frequency spectrum. Angular Domain Order Tracking analysis (AD-OT) is one of the most frequently used fault diagnosis methods in the monitoring of rotating machines and the analysis of dynamic vibration signals. In the presented experimental study, motor phase current and rotor speed were monitored at various speeds and load levels with a healthy and static eccentricity fault in the closed loop driven induction motor with vector control. The AD-OT method was applied to the motor current and the results were compared with the traditional FFT and Fourier Transform based Order Tracking (FT-OT) methods. The experimental results demonstrate that AD-OT method is more efficient than the FFT and FT-OT methods for fault diagnosis, especially while the motor is operating run-up and run-down. Also the AD-OT does not incur any additional cost for the user because in inverter driven systems, current and speed sensor coexist in the system. The main innovative parts of this study are that AD-OT method was implemented on the motor current signal for the first time.
机译:在这项研究中,提出了一种检测由变频器驱动的闭环感应电动机中的静态偏心故障的新方法。与由线路供电的电动机相反,如果电流的速度和负载以及振幅和频率不断变化,那么这也会导致频谱中故障谐波的位置连续变化。角域阶次跟踪分析(AD-OT)是监视旋转机械和分析动态振动信号中最常用的故障诊断方法之一。在提出的实验研究中,在带有矢量控制的闭环驱动感应电动机中,通过健康和静态的偏心故障,在各种速度和负载水平下监视电动机相电流和转子速度。将AD-OT方法应用于电动机电流,并将结果与​​传统的基于FFT和傅立叶变换的阶次跟踪(FT-OT)方法进行比较。实验结果表明,AD-OT方法比FFT和FT-OT方法更有效地进行故障诊断,尤其是在电动机启动和停机时。另外,由于在变频器驱动的系统中,电流和速度传感器共存于系统中,因此AD-OT不会为用户带来任何额外成本。这项研究的主要创新部分是首次在电机电流信号上实现了AD-OT方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号