首页> 外文期刊>Materials and structures >A novel test method for tendon re-anchorage in bonded post tensioned concrete using ESPI full field measurement
【24h】

A novel test method for tendon re-anchorage in bonded post tensioned concrete using ESPI full field measurement

机译:采用ESPI全场测量的粘结后张紧混凝土中肌腱重新锚固的新型试验方法

获取原文
获取原文并翻译 | 示例

摘要

In this paper, a novel test method is proposed to measure the re-anchorage of a ruptured tendon in bonded post-tensioned concrete. Full-field measurements on post-tensioned concrete prisms (500 ⅹ 100 ⅹ 100 mm) allow a large number of parameters to be considered. The full-field displacement on the concrete surface after the rupture was recorded using 3D Electronic Speckle Pattern Inter-ferometry (ESPI), which is an optical contactless technique. The results in the paper also demonstrate the power of the ESPI measurements, which allow many more measurements to be made (in this study 256 × 51 point measurements of displacement in concrete prisms) in comparison to conventional techniques such as DEMEC and electrical resistance strain gauges. The comparison of the proposed test method results to the 3D non-linear finite element model predictions shows the strength of the proposed test method for studying the re-anchorage phenomenon of ruptured tendons.
机译:本文提出了一种新的试验方法,用于测量粘结后混凝土中破裂肌腱的重新锚固。张紧后混凝土棱镜(500‰100÷100 mm)的全场测量允许考虑大量参数。使用3D电子散斑图案(ESPI)记录破裂后混凝土表面上的全场位移,这是一种光学非接触技术。本文的结果还展示了ESPI测量的功率,其允许进行更多的测量(在该研究中,与诸如Demec和电阻应变仪(电阻应变仪)的常规技术相比,如常规技术相比,进行了更多的测量(在混凝土棱镜中的位移中的位移中的位移中的置换量256×51次) 。所提出的测试方法的比较结果对3D非线性有限元模型预测显示了研究破裂肌腱的重新锚固现象的所提出的测试方法的强度。