...
首页> 外文期刊>Journal of texture studies >Comparison of methods for measuring shear force and sarcomere length and their relationship with sensorial tenderness of longissimus muscle in beef
【24h】

Comparison of methods for measuring shear force and sarcomere length and their relationship with sensorial tenderness of longissimus muscle in beef

机译:牛肉剪切力和肌节长度的测量方法比较及其与长肌的感觉压痛的关系

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Slice shear force (SSF) and laser diffraction, considered faster methodologies, for measuring beef instrumental tenderness and sarcomere length, were compared with reference methodologies Warner-Bratzler shear force (WBSF) and phase contrast microscopy. Striploin samples (n = 74) were analyzed for pH, sarcomere length, instrumental tenderness, myofibrillar fragmentation index, and sensorial tenderness. Pearson's correlation measured the association of meat evaluation methods with residual analysis of the multivariate analysis of variance model. The n-dimensional profile to evaluated methods was presented by biplot to identify the behavior of the correlation between the methods (variables). There was moderate correlation between SSF and WBSF (r = .63; p < .01) and both presented moderate correlation with sensorial tenderness (r = - .62 and -.55, to SSF and WBSF, respectively; p < .01). However, WBSF was more efficient to classify samples as tender (68%) than SSF (47%), comparing with sensorial tenderness (80%). There was a moderate correlation for laser and microscopy for sarcomere length (r = .57; p < .01). Sarcomeres were shorter when measured by laser than microscopy. Either with low correlation coefficients, sarcomere measured by laser (r = .29; p < .05) presented higher correlation with sensorial tenderness than with microscopy (r = .22; p < .10). Results highlighted that SSF was faster and easier to run, while WBSF was more appropriate to classify samples by sensorial tenderness grades. Laser diffraction is more suitable to explain effects on tenderness; however, microscopy revealed results of sarcomere length that were more realistic, once laser can underestimate sarcomeres.
机译:切片剪切力(SSF)和激光衍射,被认为是测量牛肉仪器嫩度和肌节长度的较快方法,并与参考方法Warner-Bratzler剪切力(WBSF)和相差显微镜进行了比较。分析了牛腰肉样品(n = 74)的pH,肌小节长度,器械压痛,肌原纤维碎裂指数和感觉压痛。皮尔逊相关性测量了肉类评估方法与方差模型多元分析的残差分析之间的关联。通过双线图显示了评估方法的n维轮廓,以识别方法(变量)之间相关性的行为。 SSF和WBSF之间存在中等相关性(r = .63; p <.01),并且都与感觉压痛呈中等相关性(r =-.62和-.55,分别对SSF和WBSF; p <.01) 。然而,与感觉性压痛(80%)相比,WBSF比SSF(47%)更有效地将样本分类为压痛(68%)。激光和显微镜检查的肌节长度呈中等相关性(r = .57; p <.01)。当用激光测量时,肉瘤短于显微镜。无论是低相关系数,激光测量的肌瘤(r = .29; p <.05)与感觉压痛的相关性均高于显微镜(r = .22; p <.10)。结果表明,SSF更快,更容易运行,而WBSF更适合按感觉压痛等级对样品进行分类。激光衍射更适合于解释对压痛的影响。但是,显微镜检查发现,一旦激光可以低估肉瘤,则肌节长度的结果更为真实。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号