首页> 外文期刊>Journal of Pipeline Systems Engineering and Practice >Change in Toughness Parameters of Sewer Pipes Rehabilitated with Two Types of Epoxy CIPP Liners
【24h】

Change in Toughness Parameters of Sewer Pipes Rehabilitated with Two Types of Epoxy CIPP Liners

机译:两种环氧CIPP衬板修复的下水道韧性参数的变化

获取原文
获取原文并翻译 | 示例

摘要

The main objective of the investigation was to evaluate the influence of the installation of two kinds of epoxy cured-in-place pipe (CIPP) liners (adhesive and independent) on the change in load capacity of concrete and vitrified clay pipes, and ring stiffness of polyvinyl chloride pipes. Adhesive liners stick to internal surfaces of the pipes, whereas independent liners do not stick to those. Load capacity and ring stiffness tests were carried out on samples made of pipes without liners (control samples) and those with liners. Pipe surface roughness was measured for control samples. Pull-off tests were performed on samples with adhesive liners. Mean liner thickness was determined for every sample with a liner. Results of the investigation show that change in load capacity or ring stiffness of the pipes with liners is positively correlated with adhesion strength between the pipe and the liner. Adhesion strength depends on the pipe internal surface roughness. The same load capacity or ring stiffness increase of the sewer pipes may be obtained by the installation of thinner adhesive or thicker independent liner. The results made it possible to determine adhesive liner thickness reducing coefficients. (C) 2017 American Society of Civil Engineers.
机译:研究的主要目的是评估安装两种环氧地埋管(CIPP)衬里(胶粘和独立)对混凝土和玻璃化粘土管的承载能力变化以及环刚度的影响。聚氯乙烯管。粘性衬里粘附在管道的内表面,而独立衬里则不粘附在管道的内表面。对不带衬管的管道样品(对照样品)和带衬管的样品进行了承载能力和环刚度测试。测量对照样品的管道表面粗糙度。对带有粘合剂衬里的样品进行拉拔测试。确定具有衬里的每个样品的平均衬里厚度。研究结果表明,带有衬管的管道的承载能力或环刚度的变化与管道和衬管之间的粘附强度呈正相关。粘合强度取决于管道内表面的粗糙度。通过安装较薄的粘合剂或较厚的独立衬管,可以获得与下水道管道相同的负载能力或环刚度。结果使得确定粘合剂衬里厚度减小系数成为可能。 (C)2017年美国土木工程师学会。

著录项

  • 来源
    《Journal of Pipeline Systems Engineering and Practice》 |2017年第4期|04017015.1-04017015.15|共15页
  • 作者单位

    Kielce Univ Technol, Dept Piped Util Syst, Fac Environm Geomat & Energy Engn, PL-25432 Kielce, Poland;

    Kielce Univ Technol, Dept Piped Util Syst, Fac Environm Geomat & Energy Engn, PL-25432 Kielce, Poland;

    Kielce Univ Technol, Fac Environm Geomat & Energy Engn, Dept Environm Engn & Pollut Control, PL-25432 Kielce, Poland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词