首页> 外文期刊>Journal of food protection >Comparison of Antimicrobial Treatments Applied via Conventional or Handheld Electrostatic Spray To Reduce Shiga Toxin-Producing Escherichia coli on Chilled Beef Outside Rounds
【24h】

Comparison of Antimicrobial Treatments Applied via Conventional or Handheld Electrostatic Spray To Reduce Shiga Toxin-Producing Escherichia coli on Chilled Beef Outside Rounds

机译:通过常规或手持静电喷雾减少在冷藏牛肉外轮上减少产生志贺菌毒素的大肠杆菌的抗菌处理方法的比较

获取原文
获取原文并翻译 | 示例
       

摘要

The purpose of this study was to compare the efficacy of different antimicrobial interventions applied via either conventional spray (CS) or handheld electrostatic spray (ESS) to reduce Shiga toxin-producing Escherichia coli (STEC) on fresh beef surfaces. Hot-boned outside rounds (ORs) were inoculated within 1 h after harvest with a cocktail of eight isolates consisting of 8 O157 and non-O157 serogroups of STEC (STEC8). ORs were hung on sterile meat hooks at 4 degrees C for 36 h to simulate a contaminated full carcass side in the chiller. ORs were then treated with lactic acid (LA; 4.5%, w/v), 3.0% lauric arginate ester (LAE), 0.8% cetylpyridinium chloride, 200 mg/L peracetic acid, 3 mg/L chlorine dioxide, 5 mg/L ClO2, or tap water by using CS or ESS. Temperatures of LA and peracetic acid were set at 55 and 42 degrees C before spraying, whereas all other solutions were applied at room temperature (25 degrees C). Pretreatment and posttreatment STEC8-inoculated beef tissue samples were aseptically collected to evaluate the efficacy of interventions by application method (CS or ESS). LA applied with CS achieved the greatest reduction in STEC8 numbers (3.3 log CFU/cm(2)) compared with all other treatments: 0.2 log CFU/cm(2) (tap water) to 2.3 log CFU/cm(2) (LAE). Only for LA did a significant difference arise in mean STEC8 reductions between CS and ESS applications (3.2 versus 1.7 log CFU/cm(2), respectively). Among the treatments applied with ESS, LAE produced the greatest reduction of STEC8. Antimicrobial interventions applied via conventional wand or cabinet-applied technologies can reduce the O157 and non-O157 STEC on fresh beef carcass surfaces, reducing transmission to beef consumers.
机译:这项研究的目的是比较通过常规喷雾(CS)或手持静电喷雾(ESS)施加的不同抗菌干预措施减少新鲜牛肉表面上产生志贺毒素的大肠杆菌(STEC)的功效。在收获后的1小时内,用8个STEC的8个O157和非O157血清群组成的分离菌混合物接种热结合的外部子弹(ORs)。将OR悬挂在4摄氏度的无菌肉钩上36小时,以模拟冷却器中被污染的完整car体侧。然后用乳酸(LA; 4.5%,w / v),3.0%精氨酸月桂酸酯(LAE),0.8%鲸蜡基吡啶鎓,200 mg / L过氧乙酸,3 mg / L二氧化氯,5 mg / L处理OR ClO2,或使用CS或ESS自来水。喷涂前,LA和过乙酸的温度设置为55和42摄氏度,而所有其他溶液均在室温(25摄氏度)下使用。无菌收集经预处理和后处理的STEC8接种的牛肉组织样品,以通过应用方法(CS或ESS)评估干预措施的功效。与所有其他处理相比,与CS一起施用的LA实现了STEC8数量的最大减少(3.3 log CFU / cm(2)):0.2 log CFU / cm(2)(自来水)至2.3 log CFU / cm(2)(LAE )。仅对于洛杉矶,CS和ESS应用之间的STEC8平均减少量就产生了显着差异(分别为3.2和1.7 log CFU / cm(2))。在用ESS进行的治疗中,LAE产生的STEC8减少最多。通过传统的魔杖或内阁应用技术进行的抗菌干预可以减少新鲜牛肉car体表面上的O157和非O157 STEC,从而减少向牛肉消费者的传播。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号