首页> 外文期刊>Journal of food process engineering >Time matters when ultrasonicating beef: The best time for tenderness is not the best for reducing microbial counts
【24h】

Time matters when ultrasonicating beef: The best time for tenderness is not the best for reducing microbial counts

机译:牛肉超声波处理的时间很重要:嫩嫩的最佳时间并不是减少微生物数量的最佳时间

获取原文
获取原文并翻译 | 示例
           

摘要

Research on the effects of high-intensity ultrasound (HIU) on meat quality properties shows contradictory results. The latter has been sometimes attributed to limited exposure time, not enough to cause cellular modifications. This study evaluated the effect of different exposure times (0, 10, 20, and 40 min) of HIU (37 kHz, 90 W cm(-2)) on physicochemical properties including; pH, color, tenderness, and microbial counts of two different portions of beef Longissimus lumborum (cranial-caudal). No significant effect of loin portion was observed (p > .05). Ultrasonication time caused a 20.7% toughness reduction of beef (p < .05). However, ultrasonication time also increased hue from 0.62 to 0.76 from red to orange values (p < .05), but it did not affect important coordinates such as a* or C*. Ultrasound caused an increase in the pH from 5.46 to 5.6 (p < .05), but pH was not affected by the time. The highest tenderness was achieved at 40 min of sonication. Significant reductions of mesophiles, psychrophiles, and coliforms were observed after ultrasonication when compared to control (p < .05). The best ultrasonic condition for microbial reduction was at 10 min, when the lowest microorganism counts were achieved, with a subsequent growth when increasing ultrasonication time. Practical Applications High-intensity ultrasound application appears to be a promising method to increase tenderness in beef. However, optimum time, intensity, and methodology for its application have to be defined, because the variations may affect other quality characteristics such as color or microbial contamination. To find ideal parameter values may help the industry to take decisions on the design of specialized equipment for ultrasonication of meat.
机译:对高强度超声(HIU)对肉质特性影响的研究显示出矛盾的结果。后者有时被归因于有限的暴露时间,不足以引起细胞修饰。这项研究评估了HIU(37 kHz,90 W cm(-2))的不同暴露时间(0、10、20和40分钟)对理化特性的影响,包括:两个不同部分的牛肉Longissimus lumborum(颅尾)的pH值,颜色,嫩度和微生物数量。没有观察到腰部的明显影响(p> .05)。超声处理时间使牛肉的韧性降低了20.7%(p <.05)。但是,超声时间也将色相从红色值增加到橙色值,从0.62增加到0.76(p <.05),但是它并不影响重要的坐标,例如a *或C *。超声波导致pH从5.46增加到5.6(p <.05),但pH不受时间的影响。在超声处理40分钟时达到最高的压痛。与对照组相比,超声处理后观察到嗜温菌,嗜冷菌和大肠菌的显着减少(p <.05)。减少微生物的最佳超声条件是在10分钟时达到最低的微生物数量,然后随着超声时间的增加而随后生长。实际应用高强度超声应用似乎是增加牛肉嫩度的一种有前途的方法。但是,必须定义最佳的时间,强度和应用方法,因为这些变化可能会影响其他质量特性,例如颜色或微生物污染。寻找理想的参数值可以帮助行业在设计用于肉类超声波处理的专用设备时做出决定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号