A method for the determination of total mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/ amalgamation atomic absorption spectrometry (TDA AAS) has been validated following international foodstuff protocols in order to fulfill the Brazilian National Residue Control Plan. The experimental parameters have been previously studied and optimized according to specific legislation on validation and inorganic contaminants in foodstuff. Linearity, sensitivity, specificity, detection and quantification limits, precision (repeatability and within-laboratory reproducibility), robustness as well as accuracy of the method have been evaluated. Linearity of response was satisfactory for the two range concentrations available on the TDA AAS equipment, between approximately 25.0 and 200.0 μg kg~(-1) (square regression) and 250.0 and 2000.0 μg kg~(-1) (linear regression) of mercury. The residues for both ranges were homoscedastic and independent, with normal distribution. Correlation coefficients obtained for these ranges were higher than 0.995. Limits of quantification (LOQ) and of detection of the method (LDM), based on signal standard deviation (SD) for a low-in-mercury sample, were 3.0 and 1.0 μg kg~(-1), respectively. Repeatability of the method was better than 4%. Within-laboratory reproducibility achieved a relative SD better than 6%. Robustness of the current method was evaluated and pointed sample mass as a significant factor. Accuracy (assessed as the analyte recovery) was calculated on basis of the repeatability, and ranged from 89% to 99%. The obtained results showed the suitability of the present method for direct mercury measurement in fresh fish and shrimp samples and the importance of monitoring the analysis conditions for food control purposes. Additionally, the competence of this method was recognized by accreditation under the standard ISO/IEC 17025.
机译:按照国际食品标准,已经验证了通过固体采样热分解/汞齐原子吸收光谱法(TDA AAS)测定鲜鱼和虾样品中总汞的方法,以实现巴西国家残留控制计划。实验参数先前已根据有关验证和食品中无机污染物的具体法规进行了研究和优化。评估了线性,灵敏度,特异性,检测和定量限,精度(重复性和实验室内可重复性),稳健性以及方法的准确性。对于TDA AAS设备上可用的两个浓度范围的汞,响应的线性均令人满意,介于大约25.0至200.0μgkg〜(-1)(平方回归)和250.0至2000.0μgkg〜(-1)(线性回归)之间。两个范围内的残基均是同方的并且是独立的,具有正态分布。在这些范围内获得的相关系数高于0.995。基于低汞样品的信号标准偏差(SD)的定量限(LOQ)和方法检测限(LDM)分别为3.0和1.0μgkg〜(-1)。该方法的重复性优于4%。实验室内可重复性的相对标准偏差优于6%。评估了当前方法的稳健性,指出样品质量是一个重要因素。根据重复性计算准确性(评估为分析物回收率),范围为89%至99%。所获得的结果表明,本方法适用于直接测量鲜鱼和虾样品中的汞,以及出于食品控制目的而监测分析条件的重要性。此外,该方法的功能已通过ISO / IEC 17025标准的认可。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号