首页> 外文期刊>Food Control >Application of Cold Vapor-Atomic Absorption (CVAAS) Spectrophotometry and Inductively Coupled Plasma-Atomic Emission Spectrometry methods for cadmium, mercury and lead analyses of fish samples. Validation of the method of CVAAS
【24h】

Application of Cold Vapor-Atomic Absorption (CVAAS) Spectrophotometry and Inductively Coupled Plasma-Atomic Emission Spectrometry methods for cadmium, mercury and lead analyses of fish samples. Validation of the method of CVAAS

机译:冷蒸气原子吸收分光光度法和电感耦合等离子体原子发射光谱法在鱼类样品中镉,汞和铅分析中的应用。 CVAAS方法的验证

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents the results of the implementation and application of methods for cadmium (Cd), mercury (Hg) and lead (Pb) analyses in fish samples. The determination of elements by Inductively Coupled Plasma-Atomic Emission Spectrometry and Cold Vapor-Atomic Absorption Spectrophotometry (CVAAS) was carried out using calibration curves, prepared from certified stock standard solutions of the elements. A Certified Reference Material (DOLT-2) has been successfully analyzed with CVAAS method. Sample preparation was performed by microwave-assisted acid digestion using a mixture of HNO3, H2O2 concentrated for the determination of Hg and HNO3 with HClO4 for Pb and Cd analyses using platinum vessel for the digestion. Limits of detection and quantitation were at least a factor of ten and five below the Residual Maximum Limit, respectively, showing that the CVAAS technique is well suited for quantitation of elemental impurities of mercury. It was obtained a good linearity with a linear regression coefficients higher than 0.99. An acceptable reproducibility, repeatability and trueness were found, in agreement with "Harmonized guide of method validation and estimation of uncertainty calculation applied to determination of inorganic pollutants" that it was studied in the theoretical course of validation organized by the project RLA 5060, for the validation of CVAAS method in Hg analyses of fish samples. Mercury showed the higher values in fish samples analyzed, finding content below the permissible maximum limits established by the World Health Organization (less than 0.5 mu g/g fresh wet weight). (C) 2014 Elsevier Ltd. All rights reserved.
机译:本文介绍了鱼类样品中镉(Cd),汞(Hg)和铅(Pb)分析方法的实施和应用结果。使用电感曲线耦合等离子体原子发射光谱法和冷蒸气原子吸收分光光度法(CVAAS)对元素进行测定,方法是使用校准曲线,该曲线是从元素的标准储备标准溶液中制备的。已通过CVAAS方法成功分析了认证参考材料(DOLT-2)。样品制备是通过微波辅助酸消解进行的,其中使用的HNO3,H2O2混合物浓缩,用于测定Hg,HNO3与HClO4的测定用于Pb,Cd分析,使用铂金容器进行消解。检出限和定量限分别比最大残留限度低至少十倍和五倍,这表明CVAAS技术非常适用于汞元素杂质的定量。获得了良好的线性,线性回归系数高于0.99。对于RLA 5060项目在理论验证过程中研究的“用于无机污染物测定的方法验证和不确定性估算的统一指导”,该方法的可重复性,可重复性和真实性均可接受。鱼样品汞分析中CVAAS方法的有效性汞在所分析的鱼类样品中显示出较高的值,发现其含量低于世界卫生组织规定的最大允许限值(鲜湿重小于0.5克/克)。 (C)2014 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号