首页> 外文期刊>Journal of dairy science >Diagnostic accuracy of refractometry for assessing bovine colostrum quality: A systematic review and meta-analysis
【24h】

Diagnostic accuracy of refractometry for assessing bovine colostrum quality: A systematic review and meta-analysis

机译:验光仪评估牛初乳质量的诊断准确性:系统评价和荟萃分析

获取原文
获取原文并翻译 | 示例
       

摘要

Provision of good quality colostrum [i.e., immuno-globulin G (IgG) concentration ≥50 g/L] is the first step toward ensuring proper passive transfer of immunity for young calves. Precise quantification of colostrum IgG levels cannot be easily performed on the farm. Assessment of the refractive index using a Brix scale with a refractometer has been described as being highly correlated with IgG concentration in colostrum. The aim of this study was to perform a systematic review of the diagnostic accuracy of Brix refractometry to diagnose good quality colostrum. From 101 references initially obtained, 11 were included in the systematic review meta-analysis representing 4,251 colostrum samples. The prevalence of good colostrum samples with IgG ≥50 g/L varied from 67.3 to 92.3% (median 77.9%). Specific estimates of accuracy [sensitivity (Se) and specificity (Sp)] were obtained for different reported cut-points using a hierarchical summary receiver operating characteristic curve model. For the cut-point of 22% (n = 8 studies), Se = 80.2% (95% CI: 71.1-87.0%) and Sp = 82.6% (71.4-90.0%). Decreasing the cut-point to 18% increased Se [96.1% (91.8-98.2%)] and decreased Sp [54.5% (26.9-79.6%)]. Modeling the effect of these Brix accuracy estimates using a stochastic simulation and Bayes theorem showed that a positive result with the 22% Brix cut-point can be used to diagnose good quality colostrum (posttest probability of a good colostrum: 94.3% (90.7-96.9%). The posttest probability of good colostrum with a Brix value <18% was only 22.7% (12.3-39.2%). Based on this study, the 2 cut-points could be alternatively used to select good quality colostrum (sample with Brix ≥22%) or to discard poor quality colostrum (sample with Brix <18%). When sample results are between these 2 values, colostrum supplementation should be considered.
机译:提供优质的初乳[即,免疫球蛋白G(IgG)浓度≥50g / L]是确保幼小牛正确地被动转移免疫的第一步。农场中不容易对初乳IgG水平进行精确定量。使用Brix刻度和折光仪评估折射率与初乳中IgG浓度高度相关。这项研究的目的是对糖度计的诊断准确性进行系统的回顾,以诊断高质量的初乳。从最初获得的101份参考文献中,有11份被纳入系统评价荟萃分析,代表4,251份初乳样品。 IgG≥50 g / L的优质初乳样品的患病率在67.3%至92.3%之间(中位数为77.9%)。使用分层汇总接收器工作特性曲线模型,针对不同的报告切点,获得了准确度[灵敏度(Se)和特异性(Sp)]的特定估计值。对于22%的临界点(n = 8研究),Se = 80.2%(95%CI:71.1-87.0%)和Sp = 82.6%(71.4-90.0%)。将切点降低到18%可以增加Se [96.1%(91.8-98.2%)]和降低Sp [54.5%(26.9-79.6%)]。使用随机模拟和贝叶斯定理对这些白利糖度准确性估计值的影响进行建模,结果表明,以22%的白利糖度切点为阳性的结果可用于诊断优质初乳(良好初乳的后验概率:94.3%(90.7-96.9) Brix值<18%的良好初乳的事后检验概率仅为22.7%(12.3-39.2%)。根据这项研究,可以选择2个切点选择优质初乳(Brix样品) ≥22%)或丢弃劣质初乳(白利糖度<18%的样品),当样品结果在这两个值之间时,应考虑补充初乳。

著录项

  • 来源
    《Journal of dairy science》 |2016年第9期|7381-7394|共14页
  • 作者

    S. Buczinski; J. M. Vandeweerd;

  • 作者单位

    Departement des Sciences Cliniques, Faculte de Medecine Veterinaire, Universite de Montreal, CP 5000, St-Hyacinthe, J2S 7C6, Quebec, Canada;

    Integrated Veterinary Research Unit, Namur Research Institute for Life Sciences, Department of Veterinary Medicine, Faculty of Sciences, Universite de Namur, Rue de Bruxelles 61, 5000 Namur, Belgium;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    immunoglobulin G; sensitivity; specificity; accuracy; Brix;

    机译:免疫球蛋白G;灵敏度;特异性准确性;糖度;